Full-range, high-speed, high-resolution 1-μm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye

被引:112
作者
Makita, Shuichi [1 ]
Fabritius, Tapio [1 ,2 ]
Yasuno, Yoshiaki [1 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Oulu, Optoelect & Measurement Tech Lab, Oulu 90014, Finland
来源
OPTICS EXPRESS | 2008年 / 16卷 / 12期
关键词
D O I
10.1364/OE.16.008406
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An alternative optical coherence tomography (OCT) to clinical ophthalmic 830 nm spectral-domain OCTs (SD-OCT) is demonstrated. An axial resolution of 7.4 mu m, ranging depth of 4.2 mm in tissue, sensitivity of 98.5 dB, and detection speed of 38,300 axial scans/s have been achieved. These are comparable or superior to those of recently commercially available ophthalmic 830 nm SD-OCTs in clinics. In addition, fast volumetric imaging for the in vivo human posterior eye with high-contrast of the choroid is achieved. A broadband 1.04 mu m light source enables the high-contrast and high resolution imaging of the retina and choroid. The ranging depth is extended by applying a full-range imaging method with an electro-optic modulator (BM-scan method). A prototype high-speed InGaAs line scan camera with 1024 pixels is used. A newly reported sensitivity improvement property of the BM-scan method demonstrates a sensitivity enhancement of 5.1 dB. We also introduce a newly developed resampling calibration method of spectrum that is independent of the intrinsic dispersion mismatch of the interferometer. The three-dimensional structure of the in vivo human optic nerve head with a very deep cupping is successfully visualized. (C) 2008 Optical Society of America.
引用
收藏
页码:8406 / 8420
页数:15
相关论文
共 37 条
[1]   Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging [J].
Alam, Suhail ;
Zawadzki, Robert J. ;
Choi, Stacey ;
Gerth, Christina ;
Park, Susanna S. ;
Morse, Lawrence ;
Werner, John S. .
OPHTHALMOLOGY, 2006, 113 (08) :1425-1431
[2]  
*AM NAT STAND I, 2000, ANSIZ1361
[3]   Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography [J].
An, Lin ;
Wang, Ruikang K. .
OPTICS LETTERS, 2007, 32 (23) :3423-3425
[4]   Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution [J].
Bachmann, AH ;
Leitgeb, RA ;
Lasser, T .
OPTICS EXPRESS, 2006, 14 (04) :1487-1496
[5]   Full range complex spectral domain optical coherence tomography without additional phase shifters [J].
Baumann, Bernhard ;
Pircher, Michael ;
Goetzinger, Erich ;
Hitzenberger, Christoph K. .
OPTICS EXPRESS, 2007, 15 (20) :13375-13387
[6]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[7]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[9]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[10]  
GREIVENKAMP J, 1992, SERIES PURE APPL OPT, P501