An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9

被引:18
作者
Davlouros, Periklis A. [1 ]
Mavronasiou, Eleni [1 ]
Xanthopoulou, Ioanna [1 ]
Karantalis, Vasileios [1 ]
Tsigkas, Grigorios [1 ]
Hahalis, George [1 ]
Alexopoulos, Dimitrios [1 ]
机构
[1] Patras Univ Hosp, Dept Cardiol, Rion 26504, Greece
关键词
OCT; Paclitaxel; Biolimus-A9; Neointimal coverage; Malapposition; CORONARY STENT; NEOINTIMAL COVERAGE;
D O I
10.1016/j.ijcard.2010.12.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Tissue coverage and strut apposition of drug eluting stents (DES), which can be assessed with optical coherence tomography (OCT), may be associated with late stent thrombosis (LST). Methods: Prospective observational angiographic and OCT follow-up at 6 months post-implantation of a biolimus-A9 eluting stent (BES) vs. a paclitaxel eluting stent (PES), with biodegradable polymer carriers. The primary outcome was the percent difference of uncovered struts between BESs and PESs. Results: A maximum likelihood model was used for analysis, to account for data clustering. Sixteen patients were treated with BES (28 lesions/4530 struts) and 16 with PES (23 lesions/4450 struts). Overall, BESs compared to PESs had more uncovered [0.41% vs. 0.21%, difference estimate (DE) 0.2 (95% CI, 0.06-0.34), p=0.006], malapposed [0.18% vs. 0.04%, DE 0.14 (95% CI 0.05-0.23), p=0.003], uncovered and malapposed [0.08% vs. 0.026%, DE 0.057 (95% CI 0.015-0.1), p=0.01] and protruding struts [0.23% vs. 0.04%, DE 0.185 (95% CI 0.1-0.27), p<0.001], and significantly lower neointimal thickness (59.3 +/- 28.2 mu m vs. 201.7 +/- 97.5, p<0.001). None of the BESs was totally covered with neointima, in contrast to 5 (21.7%) PESs (p=0.01). Thrombus was detected in 1 (3.6%) BES and 5 (21.7%) PESs (p=0.05); however, no patient experienced clinical stent thrombosis. Conclusion: Between two stents with biodegradable polymer, OCT demonstrated that BESs had more uncovered and malapposed struts compared to PESs at 6 months. This difference might be partly attributed to the more potent antiproliferative properties of biolimus-A9; however, its impact on clinical outcome and on the risk of LST is yet to be determined. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 20 条
[1]  
Barlis P, 2009, EUR HEART J, V31, P165
[2]   Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage [J].
Barlis, Peter ;
Dimopoulos, Konstantinos ;
Tanigawa, Jun ;
Dzielicka, Ewa ;
Ferrante, Giuseppe ;
Del Furia, Francesca ;
Di Mario, Carlo .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) :151-156
[3]  
Chevalier Bernard, 2007, EuroIntervention, V2, P426
[4]   Randomized Comparison of the Nobori Biolimus A9-Eluting Coronary Stent With the Taxus Liberte Paclitaxel-Eluting Coronary Stent in Patients With Stenosis in Native Coronary Arteries The NOBORI 1 Trial - Phase 2 [J].
Chevalier, Bernard ;
Silber, Sigmund ;
Park, Seung-Jung ;
Garcia, Eulogio ;
Schuler, Gerhard ;
Suryapranata, Harry ;
Koolen, Jacques ;
Hauptmann, Karl E. ;
Wijns, William ;
Morice, Marie-Claude ;
Carrie, Didier ;
van Es, Gerrit-Anne ;
Nagai, Hirofumi ;
Detiege, Danny ;
Paunovic, Dragica ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (03) :188-U57
[5]   Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis [J].
Cook, Stephane ;
Ladich, Elena ;
Nakazawa, Gaku ;
Eshtehardi, Parham ;
Neidhart, Michel ;
Vogel, Rolf ;
Togni, Mario ;
Wenaweser, Peter ;
Billinger, Michael ;
Seiler, Christian ;
Gay, Steffen ;
Meier, Bernhard ;
Pichler, Werner J. ;
Jueni, Peter ;
Virmani, Renu ;
Windecker, Stephan .
CIRCULATION, 2009, 120 (05) :391-399
[6]  
Davlouros P, 2010, INT J CARDIOL
[7]   Reproducibility of quantitative optical coherence tomography for stent analysis [J].
Gonzalo, Nieves ;
Garcia-Garcia, Hector M. ;
Serruys, Patrick W. ;
Commissaris, Koen H. ;
Bezerra, Hiram ;
Gobbens, Pierre ;
Costa, Marco ;
Regar, Evelyn .
EUROINTERVENTION, 2009, 5 (02) :224-232
[8]   BioMatrix® Biolimus A9®-eluting coronary stent:: a next-generation drug-eluting stent for coronary artery disease [J].
Grube, Eberhard ;
Buellesfeld, Lutz .
EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) :731-741
[9]   Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk [J].
Joner, Michael ;
Finn, Aloke V. ;
Farb, Andrew ;
Mont, Erik K. ;
Kolodgie, Frank D. ;
Ladich, Elena ;
Kutys, Robert ;
Skorija, Kristi ;
Gold, Herman K. ;
Virmani, Renu .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :193-202
[10]  
KIM JH, 2009, INT J CARDIOL