Application of light-emitting diodes for aerosol fluorescence detection

被引:25
作者
Pan, YL
Boutou, V [1 ]
Chang, RK
Ozden, I
Davitt, K
Nurmikko, AV
机构
[1] Yale Univ, Dept Appl Phys, New Haven, CT 06520 USA
[2] Yale Univ, Ctr Laser Diagnost, New Haven, CT 06520 USA
[3] Brown Univ, Div Engn, Providence, RI 02912 USA
[4] Univ Lyon 1, LASIM, CNRS, UMR 5579, F-69622 Villeurbanne, France
关键词
D O I
10.1364/OL.28.001707
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a proof-of-concept optical spectroscopic system for bioaerosol-particle fluorescence detection, in which a pulsed high-power laser is replaced by a highly compact linear array of sequentially fired light from blue light-emitting diodes. The results suggest that low-cost, compact optical aerosol detection may be feasible with the contemporary emergence of efficient UV light-emitting diodes. (C) 2003 Optical Society of America.
引用
收藏
页码:1707 / 1709
页数:3
相关论文
共 12 条
[1]   Vertical cavity violet light emitting diode incorporating an aluminum gallium nitride distributed Bragg mirror and a tunnel junction [J].
Diagne, M ;
He, Y ;
Zhou, H ;
Makarona, E ;
Nurmikko, AV ;
Han, J ;
Waldrip, KE ;
Figiel, JJ ;
Takeuchi, T ;
Krames, M .
APPLIED PHYSICS LETTERS, 2001, 79 (22) :3720-3722
[2]  
Eversole JD, 1999, FIELD ANAL CHEM TECH, V3, P249, DOI 10.1002/(SICI)1520-6521(1999)3:4/5<249::AID-FACT4>3.0.CO
[3]  
2-O
[4]   Design of an instrument for real-time detection of bioaerosols using simultaneous measurement of particle aerodynamic size and intrinsic fluorescence [J].
Hairston, PP ;
Ho, J ;
Quant, FR .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (03) :471-482
[5]   Fluorescence from airborne microparticles: dependence on size, concentration of fluorophores, and illumination intensity [J].
Hill, SC ;
Pinnick, RG ;
Niles, S ;
Fell, NF ;
Pan, YL ;
Bottiger, J ;
Bronk, BV ;
Holler, S ;
Chang, RK .
APPLIED OPTICS, 2001, 40 (18) :3005-3013
[6]   Simultaneous light scattering and intrinsic fluorescence measurement for the classification of airborne particles [J].
Kaye, PH ;
Barton, JE ;
Hirst, E ;
Clark, JM .
APPLIED OPTICS, 2000, 39 (21) :3738-3745
[7]  
Ozden I, 2001, PHYS STATUS SOLIDI A, V188, P139, DOI 10.1002/1521-396X(200111)188:1<139::AID-PSSA139>3.0.CO
[8]  
2-H
[9]   Single-shot fluorescence spectra of individual micrometer-sized bioaerosols illuminated by a 351- or a 266-nm ultraviolet laser [J].
Pan, YL ;
Holler, S ;
Chang, RK ;
Hill, SC ;
Pinnick, RG ;
Niles, S ;
Bottiger, JR .
OPTICS LETTERS, 1999, 24 (02) :116-118
[10]  
Reyes FL, 1999, FIELD ANAL CHEM TECH, V3, P240, DOI 10.1002/(SICI)1520-6521(1999)3:4/5<240::AID-FACT3>3.0.CO