Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma

被引:123
作者
Garas, A. [1 ]
Vargha, P. [2 ]
Hollo, G. [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, H-1083 Budapest, Hungary
[2] Semmelweis Univ, Ctr Cardiovasc, H-1083 Budapest, Hungary
关键词
diagnostic accuracy; glaucoma; optical coherence tomography; RTVue Fourier-domain OCT; FOURIER-DOMAIN; SCANNING AREAS; STRATUS OCT; PERFORMANCE; ABILITY;
D O I
10.1038/eye.2010.139
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose To evaluate the diagnostic accuracy of retinal nerve fibre layer thickness (RNFLT), ganglion cell complex (GCC), and optic disc measurements made with the RTVue-100 Fourier-domain optical coherence tomography (OCT) to detect glaucoma in a Caucasian referral population. Methods One randomly selected eye of 286 Caucasian patients (93 healthy, 36 ocular hypertensive, 46 preperimetric glaucoma, and 111 perimetric glaucoma eyes) was evaluated. Results Using the software-provided classification, for the total population sensitivity did not exceed 73.6% for the optic nerve head parameters, and 62.7% for the other parameters. Specificity was high (94.6-100%) for most RNFLT and GCC parameters, but low (72.0-76.3%) for the optic disc parameters. Positive predictive value varied between 98.1 and 100% for the main RNFLT parameters, 92.6 and 100% for the 16 RNFLT sectors, 92.4 and 99.0% for the GCC parameters, but did not exceed 86.3% for any of the optic disc parameters. Positive likelihood ratio (PLR) was higher than 10 for average, inferior and superior RNFLT (25.5 to infinite), 12 of the 16 RNFLT sectors (12.6 to infinite), and three of the four GCC parameters (40.0 to 48.6). No optic disc parameter had a PLR higher than 3.0. Conclusions RNFLT and GCC parameters of the RTVue-100 Fourier-domain OCT showed moderate sensitive but high specificity, positive predictive value and PLR for detection of glaucoma. The optic disc parameters had lower diagnostic accuracy than the RNFLT and GCC parameters. Eye (2011) 25, 57-65; doi: 10.1038/eye.2010.139; published online 8 October 2010
引用
收藏
页码:57 / 65
页数:9
相关论文
共 27 条
[1]
Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT [J].
Budenz, Donald L. ;
Anderson, Douglas R. ;
Varma, Rohit ;
Schuman, Joel ;
Cantor, Louis ;
Savell, Jonathan ;
Greenfeld, David S. ;
Patella, Vincent Michael ;
Quigley, Harry A. ;
Tielsch, James .
OPHTHALMOLOGY, 2007, 114 (06) :1046-1052
[2]
Sensitivity and Specificity of Time-Domain versus Spectral-Domain Optical Coherence Tomography in Diagnosing Early to Moderate Glaucoma [J].
Chang, Robert T. ;
Knight, O'Rese J. ;
Feuer, William J. ;
Budenz, Donald L. .
OPHTHALMOLOGY, 2009, 116 (12) :2294-2299
[3]
Automatic, Operator-adjusted, and Manual Disc-definition for Optic Nerve Head and Retinal Nerve Fiber Layer Measurements With the RTVue-100 Optical Coherence Tomograph [J].
Garas, Anita ;
Vargha, Peter ;
Hollo, Gabor .
JOURNAL OF GLAUCOMA, 2011, 20 (02) :80-86
[4]
Comparison of Repeatability of Retinal Nerve Fiber Layer Thickness Measurement Made Using the RTVue Fourier-domain Optical Coherence Tomograph and the GDx Scanning Laser Polarimeter With Variable or Enhanced Corneal Compensation [J].
Garas, Anita ;
Toth, Marta ;
Vargha, Peter ;
Hollo, Gabor .
JOURNAL OF GLAUCOMA, 2010, 19 (06) :412-417
[5]
Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomograph [J].
Garas, Anita ;
Vargha, Peter ;
Hollo, Gabor .
OPHTHALMOLOGY, 2010, 117 (04) :738-746
[6]
Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements [J].
Gonzalez-Garcia, Alberto O. ;
Vizzeri, Gianmarco ;
Bowd, Christopher ;
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :1067-1074
[7]
Early glaucoma detection using the Humphrey Matrix perimeter, GDx VCC, stratus OCT, and retinal nerve fiber layer photography [J].
Hong, Samin ;
Ahn, Hyunseok ;
Ha, Seung Joo ;
Yeom, Ho Yeop ;
Seong, Gong Je ;
Hong, Young Jae .
OPHTHALMOLOGY, 2007, 114 (02) :210-215
[8]
Comparison of Cirrus OCT and Stratus OCT on the Ability to Detect Localized Retinal Nerve Fiber Layer Defects in Preperimetric Glaucoma [J].
Jeoung, Jin Wook ;
Park, Ki Ho .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (02) :938-945
[9]
Effect of Disease Severity on the Performance of Cirrus Spectral-Domain OCT for Glaucoma Diagnosis [J].
Leite, Mauro T. ;
Zangwill, Linda M. ;
Weinreb, Robert N. ;
Rao, Harsha L. ;
Alencar, Luciana M. ;
Sample, Pamela A. ;
Medeiros, Felipe A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4104-4109
[10]
Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Qiu, Quanliang ;
Liu, Shu ;
Li, Haitao ;
Xu, Guihua ;
Fan, Ning ;
Huang, Lina ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2009, 116 (07) :1257-1263