High-throughput multi-analyte screening for renal disease using capillary electrophoresis

被引:46
作者
Clark, EA [1 ]
Fanguy, JC [1 ]
Henry, CS [1 ]
机构
[1] Mississippi State Univ, Dept Chem, Ctr Integrated Chem Measurements, Mississippi State, MS 39762 USA
基金
美国国家科学基金会;
关键词
capillary electrophoresis; creatinine; creatine; uric acid; PAH; high throughput screening;
D O I
10.1016/S0731-7085(01)00340-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
End-state renal disease (ESRD) affects 300 000 people in the United States each year. A large percentage of these individuals ( similar to 20%) die within the first year after diagnosis. Current methods of determining renal function rely on the measurement of a single marker using slow and frequently non-specific colorimetric methods. In this report. capillary zone electrophoresis was used to perform a multi-analyte assay for markers of renal function in urine. This method tested for creatinine (Cr). creatine (Cn), uric acid (UA), and p-aminohippuric acid (PAH) levels. The limits of detection (S/N = 3) were found to be 5 muM for Cr, 0.75 muM for Cn, and 1.5 muM for UA and PAH. Linear ranges were determined to be 5-500 muM for Cr, 0.75-500 muM for Cn, and 1.5-250 muM For UA and PAH. These ranges included the expected concentrations of the markers in human urine after 50-fold dilution. This screening method proved to be a simple and fast way to perform a high throughput analysis for multiple renal function indicators. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:795 / 801
页数:7
相关论文
共 16 条
[1]   Simultaneous determination of inulin and p-aminohippuric acid (PAH) in human plasma and urine by high-performance liquid chromatography [J].
Baccard, N ;
Hoizey, G ;
Frances, C ;
Lamiable, D ;
Trenque, T ;
Millart, H .
ANALYST, 1999, 124 (06) :833-836
[2]  
CLARK J, 1985, KIDNEYS BALANCING FL
[3]   BIENZYME REACTOR FOR ELECTROCHEMICAL DETECTION OF LOW CONCENTRATIONS OF URIC-ACID AND GLUCOSE [J].
ELEKES, O ;
MOSCONE, D ;
VENEMA, K ;
KORF, J .
CLINICA CHIMICA ACTA, 1995, 239 (02) :153-165
[4]  
Gatti R, 1999, ELECTROPHORESIS, V20, P2917, DOI 10.1002/(SICI)1522-2683(19991001)20:14<2917::AID-ELPS2917>3.0.CO
[5]  
2-W
[6]  
HEITZMAN L, 1928, URINARY ANAL DIAGNOS
[7]   The determination of creatinine in human urine by capillary zone electrophoresis with photodiode array detection [J].
Jia, L ;
Gao, J ;
Chen, X ;
Hu, GL ;
Wang, YR ;
Wang, XR ;
Zhuang, ZX .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (07) :965-977
[8]   Miniaturized biosensors employing electropolymerized permselective films and their use for creatinine assays in human serum [J].
Madaras, MB ;
Buck, RP .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3832-3839
[9]   Microfabricated amperometric creatine and creatinine biosensors [J].
Madaras, MB ;
Popescu, IC ;
Ufer, S ;
Buck, RP .
ANALYTICA CHIMICA ACTA, 1996, 319 (03) :335-345
[10]  
*NIH NAT I DIAB DI, 1999, US REN DAT SYST