Nanoporous aluminum oxide as a novel support material for enzyme biosensors

被引:49
作者
Heilmann, A [1 ]
Teuscher, N
Kiesow, A
Janasek, D
Spohn, U
机构
[1] Fraunhofer Inst Mech Mat, D-06120 Halle An Der Saale, Saale, Germany
[2] Univ Halle Wittenberg, Inst Biotechnol, D-06120 Halle An Der Saale, Saale, Germany
关键词
anodic oxidation; nanoporous alumina; enzyme sensors; amperometric detection;
D O I
10.1166/jnn.2003.224
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
To construct novel amperometric sensors for the detection of hydrogen peroxide and pyruvate, peroxidase and pyruvate oxidase were immobilized in self-supporting nanoporous alumina membranes those made by anodic oxidation. Pyruvate oxidase and other enzymes were enclosed in poly(carbamoylsulfonate) hydrogel and sucked into the nanoporous alumina structure before polymerization. The alumina membranes were investigated by scanning electron microscopy before and after the enzyme immobilization. In an amperometric flow detector cell, pyruvate and hydrogen peroxide were detected under flow injection analysis conditions in concentration ranges from 1 muM to 100 muM and 5 muM to 500 muM, respectively. The achieved operational stability showed that alumina membranes can be used to construct enzyme-modified electrodes.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 30 条
[1]   Metal-nanocluster-filled carbon nanotubes: Catalytic properties and possible applications in electrochemical energy storage and production [J].
Che, GL ;
Lakshmi, BB ;
Martin, CR ;
Fisher, ER .
LANGMUIR, 1999, 15 (03) :750-758
[2]   Improved operational stability of biosensors based on enzyme-polyelectrolyte complex adsorbed into a porous carbon electrode [J].
Gavalas, VG ;
Chaniotakis, NA ;
Gibson, TD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (11) :1205-1211
[3]   Phosphate biosensor based on polyelectrolyte-stabilized pyruvate oxidase [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2001, 427 (02) :271-277
[4]  
Hanaoka TA, 1998, APPL ORGANOMET CHEM, V12, P367, DOI 10.1002/(SICI)1099-0739(199805)12:5<367::AID-AOC732>3.0.CO
[5]  
2-Y
[6]  
Heilmann A, 1998, ADV MATER, V10, P398, DOI 10.1002/(SICI)1521-4095(199803)10:5<398::AID-ADMA398>3.0.CO
[7]  
2-6
[8]   Pore-spanning lipid bilayers visualized by scanning force microscopy [J].
Hennesthal, C ;
Steinem, C .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (33) :8085-8086
[9]  
Hulteen JC., 1998, Nanoparticles and nanostructured films: preparation, characterization and applications NewYork, P235, DOI [10.1002/9783527612079, DOI 10.1002/9783527612079]
[10]   Direct electrochemistry of cytochrome c at a glassy carbon electrode covered with a microporous alumina membrane [J].
Ikeda, O ;
Ohtani, M ;
Yamaguchi, T ;
Komura, A .
ELECTROCHIMICA ACTA, 1998, 43 (08) :833-839