Comparison of core-shell particles and sub-2 μm fully porous particles for use as ultrafast second dimension columns in two-dimensional liquid chtomatography

被引:12
作者
Ahmad, Imad A. Haidar [1 ]
Soliven, Arianne [1 ]
Allen, Robert C. [1 ]
Filgueira, Marcelo [1 ]
Carr, Peter W. [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
Liquid chromatography; High temperature liquid chromatography; Ultra fast liquid chromatography; Core-shell particles; Sub 2 mu m particles; Two dimensional liquid chromatography; PHASE GRADIENT ELUTION; PEAK-CAPACITY; SILICA PARTICLES; PEPTIDE SEPARATIONS; SAMPLING TIME; CHROMATOGRAPHY; PERFORMANCE; EFFICIENCY; OPTIMIZATION; IMPACT;
D O I
10.1016/j.chroma.2014.11.069
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
The peak capacity of small columns packed with 2.7 mu m core-shell particles and 1.8 mu m fully porous particles were compared at high temperatures using very steep (fast) gradient conditions and quite high linear velocities using the same instrument configuration as used to transfer first dimension effluent to the second dimension column as done in on-line comprehensive two-dimensional liquid chromatography. The experimental peak capacities of small columns (2.1 mm x 30 mm) packed with both types of particles were measured with fast gradients (9 s to 2 min) at high temperature (95 degrees C) using both the same flow rate (1.75 mL/min) and then at different flow rates at the same pressure (400 bar). Equal or slightly better peak capacities were achieved with the core-shell particle columns as compared to the fully porous particle columns at the same backpressure or the same flow rate. However, core-shell particles offer a real advantage over the smaller, fully porous particles because they can be operated at higher flow rates thus gradient mixer flush out and column reequilibration can be done in less time thereby allowing a greater fraction of the second dimension cycle time to be dedicated to the gradient time. (c) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 28 条
[1]
Impact of reversed phase column pairs in comprehensive two-dimensional liquid chromatography [J].
Allen, Robert C. ;
Barnes, Brian B. ;
Ahmad, Imad A. Haidar ;
Filgueira, Marcelo R. ;
Carr, Peter W. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1361 :169-177
[2]
Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance [J].
Cabooter, D. ;
Fanigliulo, A. ;
Bellazzi, G. ;
Allieri, B. ;
Rottigni, A. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) :7074-7081
[3]
Perspectives on Recent Advances in the Speed of High-Performance Liquid Chromatography [J].
Carr, Peter W. ;
Stoll, Dwight R. ;
Wang, Xiaoli .
ANALYTICAL CHEMISTRY, 2011, 83 (06) :1890-1900
[4]
Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations [J].
Davis, Joe M. ;
Stoll, Dwight R. ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2008, 80 (02) :461-473
[5]
Characteristics of superficially-porous silica particles for fast HPLC:: Some performance comparisons with sub-2-μm particles [J].
DeStefano, J. J. ;
Langlois, T. J. ;
Kirkland, J. J. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (03) :254-260
[6]
Comparison of performance of high-performance liquid chromatography columns packed with superficially and fully porous 2.5 μm particles using kinetic plots [J].
Fanigliulo, Ameriga ;
Cabooter, Deirdre ;
Bellazzi, Guido ;
Tramarin, Davide ;
Allieri, Brigida ;
Rottigni, Alessandro ;
Desmet, Gert .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (23-24) :3655-3665
[7]
Improving Peak Capacity in Fast Online Comprehensive Two-Dimensional Liquid Chromatography with Post-First-Dimension Flow Splitting [J].
Filgueira, Marcelo R. ;
Huang, Yuan ;
Witt, Klaus ;
Castells, Cecilia ;
Carr, Peter W. .
ANALYTICAL CHEMISTRY, 2011, 83 (24) :9531-9539
[8]
Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography [J].
Gilar, M ;
Daly, AE ;
Kele, M ;
Neue, UD ;
Gebler, JC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :183-192
[9]
Comparative study of the performance of columns packed with several new fine silica particles Would the external roughness of the particles affect column properties? [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1166 (1-2) :30-46
[10]
Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters [J].
Gritti, Fabrice ;
Felinger, Attila ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1136 (01) :57-72