RF microcoil design for practical NMR of mass-limited samples

被引:52
作者
Subramanian, R [1 ]
Lam, MM [1 ]
Webb, AG [1 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Magnet Resonance Engn Lab, Urbana, IL 61801 USA
关键词
microcoils; nanovolume NMR; mass-limited samples; solenoids; magnetic susceptibility;
D O I
10.1006/jmre.1998.1450
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper addresses practical issues involved in obtaining high resolution H-1 NMR spectra from samples containing less than 10 nmol, Solenoidal microcoils have been constructed to: (a) assess the effects of magnetic susceptibility mismatches at 500 MHz, (b) increase the concentration sensitivity of microcoil probes, (c) incorporate a lock channel for 2D experiments and long 1D acquisitions, and (d) assess the total amount of the sample required (with respect to the coil length) to avoid line broadening due to edge effects. Compared to previously published microcoil results, sample volumes have been increased by a factor of 20 with a concomitant decrease in the required concentration (5-20 mM), Perfluorocarbon susceptibility matching remained effective at 500 MHz, allowing acquisition of high resolution NMR spectra, A lock channel has also been successfully incorporated in microcoil probes. The limits of detection for sucrose with a 10 min acquisition time were found to be 17.8 and 34.1 pmol for the single and double resonance coils, respectively. A sample length of approximately 10 times than that of the coil was required to avoid magnetic susceptibility artifacts. (C) 1998 Academic Press.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 8 条
  • [1] CYLINDRICAL DEMAGNETIZATION FIELDS AND MICROPROBE DESIGN IN HIGH-RESOLUTION NMR
    BARBARA, TM
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 109 (02) : 265 - 269
  • [2] HIGH-RESOLUTION H-1-NMR IN SOLID-PHASE ORGANIC-SYNTHESIS
    FITCH, WL
    DETRE, G
    HOLMES, CP
    SHOOLERY, JN
    KEIFER, PA
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 1994, 59 (26) : 7955 - 7956
  • [3] ODLEBAD E, 1966, NORDISK FORENING FOR
  • [4] HIGH-RESOLUTION MICROCOIL H-1-NMR FOR MASS-LIMITED, NANOLITER-VOLUME SAMPLES
    OLSON, DL
    PECK, TL
    WEBB, AG
    MAGIN, RL
    SWEEDLER, JV
    [J]. SCIENCE, 1995, 270 (5244) : 1967 - 1970
  • [5] DESIGN AND ANALYSIS OF MICROCOILS FOR NMR MICROSCOPY
    PECK, TL
    MAGIN, RL
    LAUTERBUR, PC
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 108 (02): : 114 - 124
  • [6] SHOOLERY JN, 1992, MAGN MOMENTS, V5, P1
  • [7] SHOOLERY JN, 1979, TOP CARBON 13 NMR SP, V3, P28
  • [8] Signal-to-noise and magnetic susceptibility trade-offs in solenoidal microcoils for NMR
    Webb, AG
    Grant, SC
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 113 (01): : 83 - 87