Radiation cost of helical high-resolution chest CT

被引:7
作者
Leswick, DA
Webster, ST
Wilcox, BA
Fladeland, DA
机构
[1] Royal Univ Hosp, Dept Radiol, Saskatoon, SK S7N 0W8, Canada
[2] Saskatchewan Labour, Occupat Hlth & Safety Div, Saskatoon, SK SK7 2H6, Canada
[3] Regina Gen Hosp, Dept Nucl Med, Regina, SK S4P 0W5, Canada
关键词
D O I
10.2214/ajr.184.3.01840742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. In our department, most high-resolution CT (HRCT) scans of the lungs are performed in conjunction with a standard helical examination to assess the entire chest. This requires scanning the patient twice. The goal of this study was to determine if the radiation dose could be decreased by performing a single combination helical scan of the chest from which both 5-mm standard and 1.25-mm HRCT images could be obtained. CONCLUSION. Because the total measured radiation dose is 32% greater from a single combination helical HRCT scan of the chest versus separate standard helical plus axial HRCT scans, helical HRCT is not a clinically advisable technique.
引用
收藏
页码:742 / 745
页数:4
相关论文
共 12 条
  • [1] Review of radiation issues for computed tomography
    Frush, DP
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 2004, 25 (01) : 17 - 24
  • [2] High-resolution CT using multidetector CT equipment: Evaluation of image quality in II cadaveric lungs and a phantom
    Honda, O
    Johkoh, T
    Tomiyama, N
    Kozuka, T
    Mihara, N
    Koyama, M
    Hamada, S
    Naito, H
    Nakamura, H
    Kudo, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (04) : 875 - 879
  • [3] Johns HE, 1983, PHYSICS RADIOLOGY, P739
  • [4] CHRONIC INFILTRATIVE LUNG-DISEASE - COMPARISON OF DIAGNOSTIC ACCURACIES OF RADIOGRAPHY AND LOW-AND CONVENTIONAL-DOSE THIN-SECTION CT
    LEE, KS
    PRIMACK, SL
    STAPLES, CA
    MAYO, JR
    ALDRICH, JE
    MULLER, NL
    [J]. RADIOLOGY, 1994, 191 (03) : 669 - 673
  • [5] National Conference on Dose Reduction in CT, with an emphasis on pediatric patients
    Linton, OW
    Mettler, FA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 321 - 329
  • [6] HIGH-RESOLUTION CT OF THE LUNGS - AN OPTIMAL APPROACH
    MAYO, JR
    WEBB, WR
    GOULD, R
    STEIN, MG
    BASS, I
    GAMSU, G
    GOLDBERG, HI
    [J]. RADIOLOGY, 1987, 163 (02) : 507 - 510
  • [7] HIGH-RESOLUTION CT OF THE CHEST - RADIATION-DOSE
    MAYO, JR
    JACKSON, SA
    MULLER, NL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 479 - 481
  • [8] AAPM/RSNA physics tutorial for residents:: Topics in CT -: Radiation dose in CT1
    McNitt-Gray, MF
    [J]. RADIOGRAPHICS, 2002, 22 (06) : 1541 - 1553
  • [9] Radiation exposure and image quality in chest CT examinations
    Ravenel, J
    Scalzetti, EM
    Huda, W
    Garrisi, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (02) : 279 - 284
  • [10] Dose reduction in multidetector CT using attenuation-based online tube current modulation
    Tack, D
    De Maertelaer, V
    Gevenois, PA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 331 - 334