Cardiac microembolism: Prevalence and clinical outcome

被引:20
作者
Eicke, BM [1 ]
Barth, V [1 ]
Kukowski, B [1 ]
Werner, G [1 ]
Paulus, W [1 ]
机构
[1] UNIV GOTTINGEN,DEPT INTERNAL MED,GOTTINGEN,GERMANY
关键词
embolus detection; ultrasound; transcranial doppler; stroke; atrial fibrillation; prosthetic heart valve;
D O I
10.1016/0022-510X(95)00299-H
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
High intensity transient signals (HITS) have been identified ultrasonically in patients with extracranial vascular or cardiac disease and are suggestive of microembolic material. We studied the prevalence of these signals in 60 patients with increased risk for cardioembolic stroke and in a control group of 20 subjects. Patient groups (n = 20) were characterized by either non-rheumatic atrial fibrillation (AFIB) (I) or a history of prosthetic valve surgery with AFIB (II) or without AFIB (III). Embolic signals were not seen in the control group. In group I, 3 patients (15%) demonstrated HITS, in groups II and III 10 patients (50%). Microembolic signals in patients with prosthetic heart valves (II, III) had a higher signal intensity, indicating different embolic material. There was no correlation of microembolic signals with the anticoagulant treatment or the position of the prosthetic valve. HITS were found in 1/9 (11%) of the patients with a bioprosthetic valve as compared to 19/31 (61%) with a mechanical valve. After 6-12 months, 1 of 12 HITS positive patients had experienced a stroke and 2 had died. None of the 28 patients without HITS had suffered a stroke, 2 had died. Microembolic signals are frequent events in patients with mechanical prosthetic valves. In these patients they do not appear to be a major prognostic factor for an impending cardioembolic stroke.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 39 条
[1]   CLINICAL CORRELATES OF HIGH-INTENSITY TRANSIENT SIGNALS DETECTED ON TRANSCRANIAL DOPPLER SONOGRAPHY IN PATIENTS WITH CEREBROVASCULAR-DISEASE [J].
BABIKIAN, VL ;
HYDE, C ;
POCHAY, V ;
WINTER, MR .
STROKE, 1994, 25 (08) :1570-1573
[2]   12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES [J].
BLOOMFIELD, P ;
WHEATLEY, DJ ;
PRESCOTT, RJ ;
MILLER, HC .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) :573-579
[3]   CARDIAC AND ARTERIAL LESIONS IN CAROTID TRANSIENT ISCHEMIC ATTACKS [J].
BOGOUSSLAVSKY, J ;
HACHINSKI, VC ;
BOUGHNER, DR ;
FOX, AJ ;
VINUELA, F ;
BARNETT, HJM .
ARCHIVES OF NEUROLOGY, 1986, 43 (03) :223-228
[4]   THROMBOEMBOLIC AND BLEEDING COMPLICATIONS IN PATIENTS WITH MECHANICAL HEART-VALVE PROSTHESES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
BRIET, E .
CIRCULATION, 1994, 89 (02) :635-641
[5]   GAS BUBBLE EMBOLI DETECTED BY TRANSCRANIAL DOPPLER SONOGRAPHY IN PATIENTS WITH PROSTHETIC HEART-VALVES - A PRELIMINARY-REPORT [J].
DAUZAT, M ;
DEKLUNDER, G ;
ALDIS, A ;
RABINOVITCH, M ;
BURTE, F ;
BRET, PM .
JOURNAL OF ULTRASOUND IN MEDICINE, 1994, 13 (02) :129-135
[6]   EVIDENCE FOR EMBOLIZATION FROM A POSTERIOR CEREBRAL-ARTERY THROMBUS BY TRANSCRANIAL DOPPLER MONITORING [J].
DIEHL, RR ;
SLIWKA, U ;
RAUTENBERG, W ;
SCHWARTZ, A .
STROKE, 1993, 24 (04) :606-608
[7]   EMBOLUS DETECTION IN DIFFERENT DEGREES CAROTID DISEASE [J].
EICKE, BM ;
VONLORENTZ, J ;
PAULUS, W .
NEUROLOGICAL RESEARCH, 1995, 17 (03) :181-184
[8]   COAGULATION ACTIVITY AND EMBOLI COUNTS IN PATIENTS WITH PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
MALLINSON, A ;
GROSSET, DG ;
LEES, KR .
STROKE, 1994, 25 (06) :1211-1214
[9]   DIFFERENTIATION BETWEEN GASEOUS AND FORMED EMBOLIC MATERIALS IN-VIVO - APPLICATION IN PROSTHETIC HEART-VALVE PATIENTS [J].
GEORGIADIS, D ;
MACKAY, TG ;
KELMAN, AW ;
GROSSET, DG ;
WHEATLEY, DJ ;
LEES, KR .
STROKE, 1994, 25 (08) :1559-1563
[10]   PREVALENCE AND CHARACTERISTICS OF INTRACRANIAL MICROEMBOLI SIGNALS IN PATIENTS WITH DIFFERENT TYPES OF PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
GROSSET, DG ;
KELMAN, A ;
FAICHNEY, A ;
LEES, KR .
STROKE, 1994, 25 (03) :587-592