DIFFERENTIATION BETWEEN GASEOUS AND FORMED EMBOLIC MATERIALS IN-VIVO - APPLICATION IN PROSTHETIC HEART-VALVE PATIENTS

被引:63
作者
GEORGIADIS, D
MACKAY, TG
KELMAN, AW
GROSSET, DG
WHEATLEY, DJ
LEES, KR
机构
[1] UNIV GLASGOW,DEPT MED & THERAPEUT,GLASGOW,SCOTLAND
[2] UNIV GLASGOW,DEPT CARDIAC SURG,GLASGOW,SCOTLAND
关键词
EMBOLISM; HEART VALVE PROSTHESIS; ULTRASONICS;
D O I
10.1161/01.STR.25.8.1559
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics of emboli signals. Subsequently the algorithm was applied to patients with mechanical prosthetic cardiac valves. Methods Emboli signals detected in patients with carotid disease, acute stroke, and atrial fibrillation were used as formed emboli data, and signals detected in patients undergoing cardiac catheterization studies were used as gaseous emboli data. For each embolus signal, the maximal amplitude, the sum of amplitudes, and the spectral intensity distribution were calculated. Two hundred emboli signals from each category were used to develop a differentiation algorithm, which was subsequently evaluated on 501 additional solid and 995 gaseous emboli signals. The same algorithm was used to analyze 5958 emboli signals detected in 60 patients with mechanical prosthetic valves. Results The best results were obtained with an algorithm based on both the maximal amplitude and the sum of amplitudes (sensitivity, 99%; specificity, 96.5%). On subsequent evaluation, the sensitivity and specificity of the algorithm were 99.6% and 89.8%, respectively. Of the 5958 emboli signals detected in prosthetic valve patients, 92.4% were classified as gaseous. Conclusions Differentiation between gaseous and formed emboli signals, as detected by transcranial Doppler in vivo, is feasible by means of spectral analysis. Application of the differentiation algorithm in prosthetic valve patients suggests that the embolic material in these patients is gaseous. The possibility of distinguishing between different formed embolic materials with this technique remains to be evaluated.
引用
收藏
页码:1559 / 1563
页数:5
相关论文
共 29 条
[1]
ALBIN MS, 1989, NEUROSURG ANESTHESIO, V2, P134
[2]
BRUCHER R, 1993, STROKE, V24, P510
[3]
BRAIN EMBOLISM, REVISITED [J].
CAPLAN, LR .
NEUROLOGY, 1993, 43 (07) :1281-1287
[4]
TRANSIENT PLATELET ACCUMULATION IN THE RAT-BRAIN AFTER COMMON CAROTID-ARTERY THROMBOSIS - AN IN-111 LABELED PLATELET STUDY [J].
DIETRICH, WD ;
DEWANJEE, S ;
PRADO, R ;
WATSON, BD ;
DEWANJEE, MK .
STROKE, 1993, 24 (10) :1534-1540
[5]
DETECTION OF INTRACRANIAL EMBOLI IN PATIENTS WITH CAROTID DISEASE [J].
GEORGIADIS, D ;
GROSSET, DG ;
QUIN, RO ;
NICHOL, JAR ;
BONE, I ;
LEES, KR .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1994, 8 (03) :309-314
[6]
PREVALENCE AND CHARACTERISTICS OF INTRACRANIAL MICROEMBOLI SIGNALS IN PATIENTS WITH DIFFERENT TYPES OF PROSTHETIC CARDIAC VALVES [J].
GEORGIADIS, D ;
GROSSET, DG ;
KELMAN, A ;
FAICHNEY, A ;
LEES, KR .
STROKE, 1994, 25 (03) :587-592
[7]
CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES [J].
GRAF, T ;
FISCHER, H ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) :169-174
[8]
DOPPLER EMBOLI SIGNALS VARY ACCORDING TO STROKE SUBTYPE [J].
GROSSET, DG ;
GEORGIADIS, D ;
ABDULLAH, I ;
BONE, I ;
LEES, KR .
STROKE, 1994, 25 (02) :382-384
[9]
QUANTIFICATION OF ULTRASOUND EMBOLI SIGNALS IN PATIENTS WITH CARDIAC AND CAROTID DISEASE [J].
GROSSET, DG ;
GEORGIADIS, D ;
KELMAN, AW ;
LEES, KR .
STROKE, 1993, 24 (12) :1922-1924
[10]
INDUCTION OF TRANSIENT NEUROLOGICAL DYSFUNCTION IN BABOONS BY PLATELET MICROEMBOLI [J].
KESSLER, C ;
KELLY, AB ;
SUGGS, WD ;
WEISSMAN, JD ;
EPSTEIN, CM ;
HANSON, SR ;
HARKER, LA .
STROKE, 1992, 23 (05) :697-702