Observations on real-time prostate gland motion using electromagnetic tracking

被引:309
作者
Langen, Katja M. [1 ]
Willoughby, Twyla R. [1 ]
Meeks, Sanford L. [1 ]
Santhanam, Anand [1 ,2 ]
Cunningham, Alexis [3 ]
Levine, Lisa [3 ]
Kupelian, Patrick A. [1 ]
机构
[1] MD Anderson Canc Ctr, Dept Radiat Oncol, Orlando, FL 32806 USA
[2] Univ Cent Florida, Coll Opt & Photon, Orlando, FL 32816 USA
[3] Calypso Med Technol, Seattle, WA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 71卷 / 04期
关键词
prostatic neoplasms; radiotherapy; guidance; electromagnetic tracking;
D O I
10.1016/j.ijrobp.2007.11.054
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: To quantify and describe the real-time movement of the prostate gland in a large data set of patients treated with radiotherapy. Methods and Materials: The Calypso four-dimensional localization system was used for target localization in 17 patients, with electromagnetic markers implanted in the prostate of each patient. We analyzed a total of 550 continuous tracking sessions. The fraction of time that the prostate was displaced by >3, >5, >7, and >10 mm was calculated for each session and patient. The frequencies of displacements after initial patient positioning were analyzed over time. Results: Averaged over all patients, the prostate was displaced >3 and >5 mm for 13.6% and 3.3% of the total treatment time, respectively. For individual patients, the corresponding maximal values were 36.2% and 10.9%. For individual fractions, the corresponding maximal values were 98.7% and 98.6%. Displacements >3 mm were observed at 5 min after initial alignment in about one-eighth of the observations, and increased to one-quarter by 10 min. For individual patients, the maximal value of the displacements >3 mm at 5 and 10 min after initial positioning was 43% and 75%, respectively. Conclusion: On average, the prostate was displaced by >3 mm and >5 mm approximately 14% and 3% of the time, respectively. For individual patients, these values were up to three times greater. After the initial positioning, the likelihood of displacement of the prostate gland increased with elapsed time. This highlights the importance of initiating treatment shortly after initially positioning the patient. (C) 2008 Elsevier Inc.
引用
收藏
页码:1084 / 1090
页数:7
相关论文
共 20 条
[1]
Accuracy of a wireless localization system for radiotherapy [J].
Balter, JM ;
Wright, JN ;
Newell, LJ ;
Friemel, B ;
Dimmer, S ;
Cheng, Y ;
Wong, J ;
Vertatschitsch, E ;
Mate, TP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :933-937
[2]
MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]
A comparison of ventilatory prostate movement in four treatment positions [J].
Dawson, LA ;
Litzenberg, DW ;
Brock, KK ;
Sanda, M ;
Sullivan, M ;
Sandler, HM ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :319-323
[4]
Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI) [J].
Ghilezan, MJ ;
Jaffray, DA ;
Siewerdsen, JH ;
van Herk, M ;
Shetty, A ;
Sharpe, MB ;
Jafri, SZ ;
Vicini, FA ;
Matter, RC ;
Brabbins, DS ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :406-417
[5]
Intrafraction prostate motion during IMRT for prostate cancer [J].
Huang, E ;
Dong, L ;
Chandra, A ;
Kuban, DA ;
Rosen, II ;
Evans, A ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02) :261-268
[6]
Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123
[7]
Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy [J].
Kupelian, Patrick ;
Willoughby, Twyla ;
Mahadevan, Arul ;
Djemil, Toufik ;
Weinstein, Geoffrey ;
Jani, Shirish ;
Enke, Charles ;
Solberg, Timothy ;
Flores, Nicholas ;
Liu, David ;
Beyer, David ;
Levine, Lisa .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1088-1098
[8]
Initial experience with megavoltage (MV) CT guidance for daily prostate alignments [J].
Langen, KM ;
Zhang, YS ;
Andrews, RD ;
Hurley, ME ;
Meeks, SL ;
Poole, DO ;
Willoughby, TR ;
Kupelian, PA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1517-1524
[9]
Organ motion and its management [J].
Langen, KM ;
Jones, DTL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01) :265-278
[10]
A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer [J].
Lattanzi, J ;
McNeeley, S ;
Pinover, W ;
Horwitz, E ;
Das, I ;
Schultheiss, TE ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :719-725