In vivo size and shape measurement of the human upper airway using endoscopic long-range optical coherence tomography

被引:72
作者
Armstrong, JJ [1 ]
Leigh, MS
Walton, ID
Zvyagin, AV
Alexandrov, SA
Schwer, S
Sampson, DD
Hillman, DR
Eastwood, PR
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt & Biomed Engn Lab, Crawley, WA 6009, Australia
[2] Sir Charles Gairdner Hosp, Dept Pulm Physiol, W Australian Sleep Disorders Res Inst, Nedlands, WA 6009, Australia
来源
OPTICS EXPRESS | 2003年 / 11卷 / 15期
关键词
D O I
10.1364/OE.11.001817
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a long-range optical coherence tomography system for size and shape measurement of large hollow organs in the human body. The system employs a frequency-domain optical delay line of a configuration that enables the combination of high-speed operation with long scan range. We compare the achievable maximum delay of several delay line configurations, and identify the configurations with the greatest delay range. We demonstrate the use of one such long-range delay line in a catheter-based optical coherence tomography system and present profiles of the human upper airway and esophagus in vivo with a radial scan range of 26 millimeters. Such quantitative upper airway profiling should prove valuable in investigating the pathophysiology of airway collapse during sleep (obstructive sleep apnea). (C) 2003 Optical Society of America.
引用
收藏
页码:1817 / 1826
页数:10
相关论文
共 21 条
[1]   PHARYNGEAL NARROWING OCCLUSION DURING CENTRAL SLEEP-APNEA [J].
BADR, MS ;
TOIBER, F ;
SKATRUD, JB ;
DEMPSEY, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (05) :1806-1815
[2]   EXTENDED-RANGE OPTICAL LOW-COHERENCE REFLECTOMETRY USING A RECIRCULATING DELAY TECHNIQUE [J].
BANEY, DM ;
SORIN, WV .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1993, 5 (09) :1109-1112
[3]   Constant high-speed optical low-coherence reflectometry over 0.12m scan range [J].
Delachenal, N ;
Gianotti, R ;
Walti, R ;
Limberger, H ;
Salathe, RP .
ELECTRONICS LETTERS, 1997, 33 (24) :2059-2061
[4]   High resolution in vivo intra-arterial imaging with optical coherence tomography [J].
Fujimoto, JG ;
Boppart, SA ;
Tearney, GJ ;
Bouma, BE ;
Pitris, C ;
Brezinski, ME .
HEART, 1999, 82 (02) :128-133
[5]   Accurate remote distance sensing by use of low-coherence interferometry: an industrial application [J].
Giniunas, L ;
Karkockas, R ;
Danielius, R .
APPLIED OPTICS, 1998, 37 (28) :6729-6733
[6]  
HOFFSTEIN V, 1991, EUR RESPIR J, V4, P602
[7]   400-HZ MECHANICAL SCANNING OPTICAL DELAY-LINE [J].
KWONG, KF ;
YANKELEVICH, D ;
CHU, KC ;
HERITAGE, JP ;
DIENES, A .
OPTICS LETTERS, 1993, 18 (07) :558-560
[8]  
NAAJAS D, 2001, MONALDI ARCH CHEST D, V56, P555
[9]   Optimal interferometer designs for optical coherence tomography [J].
Rollins, AM ;
Izatt, JA .
OPTICS LETTERS, 1999, 24 (21) :1484-1486
[10]   In vivo video rate optical coherence tomography [J].
Rollins, AM ;
Kulkarni, MD ;
Yazdanfar, S ;
Ung-arunyawee, R ;
Izatt, JA .
OPTICS EXPRESS, 1998, 3 (06) :219-229