Quantitative, high-resolution photoacoustic spectroscopy by combining photoacoustic imaging with diffuse optical tomography

被引:4
作者
Bauer, Adam Q. [1 ]
Nothdurft, Ralph E. [1 ]
Erpelding, Todd N. [2 ]
Wang, Lihong V. [3 ]
Culver, Joseph P. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
[2] Philips Res North Amer, Briarcliff Manor, NY 10510 USA
[3] Washington Univ, Dept Biomed Engn, St Louis, MO 63130 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011 | 2011年 / 7899卷
关键词
CEREBRAL-BLOOD-FLOW; ABSORPTION COEFFICIENT; OXYGEN-SATURATION; RAT; MICROSCOPY; RECOVERY; MEDIA;
D O I
10.1117/12.875549
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The specificity of both molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. Because the PA signal is a product of both the optical absorption coefficient and the local light fluence, quantitative PA measurements of absorption require an accurate estimate of the optical fluence. Light-modeling aided by diffuse optical tomography (DOT) methods can be used to provide the required fluence map and to reduce errors in traditional PA spectroscopic analysis. As a proof-of-concept, we designed a phantom to demonstrate artifacts commonly found in photoacoustic tomography (PAT) and how fluence-related artifacts in PAT images can lead to misrepresentations of tissue properties. Specifically, we show that without accounting for fluence-related inhomogeneities in our phantom, errors in estimates of the absorption coefficient from a PAT image were as much as 33%. To correct for this problem, DOT was used to reconstruct spatial distributions of the absorption coefficients of the phantom, and along with the surface fluence distribution from the PAT system, we calculated the fluence everywhere in the phantom. This fluence map was used to correct PAT images of the phantom, reducing the error in the estimated absorption coefficient from the PAT image to less than 5%. Thus, we demonstrate experimentally that combining DOT with PAT can significantly reduce fluence-related errors in PAT images, as well as produce quantitatively accurate, high-resolution images of the optical absorption coefficient.
引用
收藏
页数:4
相关论文
共 30 条
[1]   Detection of ultrawide-band ultrasound pulses in optoacoustic tomography [J].
Andreev, VG ;
Karabutov, AA ;
Oraevsky, AA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (10) :1383-1390
[2]  
[Anonymous], 1990, PHYS PROPERTIES TISS
[3]   Quantitative photoacoustic tomography from boundary pressure measurements: noniterative recovery of optical absorption coefficient from the reconstructed absorbed energy map [J].
Banerjee, Biswanath ;
Bagchi, Srijeeta ;
Vasu, Ram Mohan ;
Roy, Debasish .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (09) :2347-2356
[4]   Polymer Microring Resonators for High-Sensitivity and Wideband Photoacoustic Imaging [J].
Chen, Sung-Liang ;
Huang, Sheng-Wen ;
Ling, Tao ;
Ashkenazi, Shai ;
Guo, L. Jay .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (11) :2482-2491
[5]   Bioconjugated gold nanoparticles as a molecular based contrast agent: Implications for imaging of deep tumors using optoacoustic tomography [J].
Copland, JA ;
Eghtedari, M ;
Popov, VL ;
Kotov, N ;
Mamedova, N ;
Motamedi, M ;
Oraevsky, AA .
MOLECULAR IMAGING AND BIOLOGY, 2004, 6 (05) :341-349
[6]   Two-dimensional quantitative photoacoustic image reconstruction of absorption distributions in scattering media by use of a simple iterative method [J].
Cox, BT ;
Arridge, SR ;
Köstli, KP ;
Beard, PC .
APPLIED OPTICS, 2006, 45 (08) :1866-1875
[7]   Volumetric diffuse optical tomography of brain activity [J].
Culver, JP ;
Siegel, AM ;
Stott, JJ ;
Boas, DA .
OPTICS LETTERS, 2003, 28 (21) :2061-2063
[8]   Diffuse optical tomography of cerebral blood flow, oxygenation, and metabolism in rat during focal ischemia [J].
Culver, JP ;
Durduran, T ;
Furuya, T ;
Cheung, C ;
Greenberg, JH ;
Yodh, AG .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2003, 23 (08) :911-924
[9]  
Eghtedari M, 2004, LASER SURG MED, P52
[10]   Sentinel Lymph Nodes in the Rat: Noninvasive Photoacoustic and US Imaging with a Clinical US System [J].
Erpelding, Todd N. ;
Kim, Chulhong ;
Pramanik, Manojit ;
Jankovic, Ladislav ;
Maslov, Konstantin ;
Guo, Zijian ;
Margenthaler, Julie A. ;
Pashley, Michael D. ;
Wang, Lihong V. .
RADIOLOGY, 2010, 256 (01) :102-110