Fully automated immunoassay system of endocrine disrupting chemicals using monoclonal antibodies chemically conjugated to bacterial magnetic particles

被引:50
作者
Matsunaga, T
Ueki, F
Obata, K
Tajima, H
Tanaka, T
Takeyama, H
Goda, Y
Fujimoto, S
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Fac Technol, Koganei, Tokyo 1848588, Japan
[2] Precis Syst Sci Co Ltd, Matsudo, Chiba 2700064, Japan
[3] Takeda Chem Ind Ltd, Osaka 5328686, Japan
关键词
bacterial magnetic particles (BMPs); endocrine disrupting chemicals (EDCs); fully automated immunoassay system; alkylphenol; ethoxylates (APES); bisphenol A (BPA); linear alkylbenzene sulfonates (LASs);
D O I
10.1016/S0003-2670(02)01036-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a rapid and high-throughput detection system for endocrine disrupting chemicals (EDCs) has been required in the recent years. A fully automated immunoassay system was described for the detection of EDCs, such as alkylphenol ethoxylates (APEs), bisphenol A (BPA) and linear alkylbenzene sulfonates (LASS), using monoclonal antibodies chemically conjugated to bacterial magnetic particles (BMPs) and alkaline phosphatase (ALP)-conjugated EDCs. EDC concentrations were evaluated by the decrease in luminescence based on the competitive reaction of EDCs and ALP-conjugated EDCs. Full automation of the BMP-based immunoassay was achieved by using an automated eight-way pipet moving at X-, Y- and Z-direction and a B/F separation unit. B/F separation was performed on the tip surface of eight-way pipet with a retractable magnet mounted close to the pipet tip. Immunoreactions were saturated after 10 min, and the assay was completed within 15 min. The detection ranges for APE, BPA and LAS were 6.6 ppb-66 ppm, 2.3 ppt-2.3 ppm, and 35 ppt-35 ppm, respectively. This BMP-based immunoassay system has advantages due to its high sensitivity and rapid measurement of samples. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 83
页数:9
相关论文
共 28 条
[21]   Sensitive determination of bisphenol A in environmental water by gas chromatography with nitrogen-phosphorus detection after cyanomethylation [J].
Shin, HS ;
Park, CH ;
Park, SJ ;
Pyo, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (01) :119-125
[22]  
SOTO AM, 1991, ENVIRON HEALTH PERSP, V92, P167, DOI 10.2307/3431154
[23]   APPLICATION OF BACTERIAL MAGNETIC PARTICLES AS NOVEL DNA CARRIERS FOR BALLISTIC TRANSFORMATION OF A MARINE CYANOBACTERIUM [J].
TAKEYAMA, H ;
YAMAZAWA, A ;
NAKAMURA, C ;
MATSUNAGA, T .
BIOTECHNOLOGY TECHNIQUES, 1995, 9 (05) :355-360
[24]  
Takeyama H, 2000, MAR BIOTECHNOL, V2, P309
[25]   Fully automated chemiluminescence immunoassay of insulin using antibody-protein A-bacterial magnetic particle complexes [J].
Tanaka, T ;
Matsunaga, T .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3518-3522
[26]   A physiologically based approach to the study of bisphenol A and other estrogenic chemicals on the size of reproductive organs, daily sperm production, and behavior [J].
Vom Saal, FS ;
Cooke, PS ;
Buchanan, DL ;
Palanza, P ;
Thayer, KA ;
Nagel, SC ;
Parmigiani, S ;
Welshons, WV .
TOXICOLOGY AND INDUSTRIAL HEALTH, 1998, 14 (1-2) :239-260
[27]   Induction of hepatic estrogen receptor in juvenile Atlantic salmon in vivo by the environmental estrogen, 4-nonylphenol [J].
Yadetie, F ;
Arukwe, A ;
Goksoyr, A ;
Male, R .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 233 (1-3) :201-210
[28]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF LINEAR ALKYLBENZENESULPHONATES IN RIVER WATER AT PPB LEVELS BY PRECOLUMN CONCENTRATION [J].
YOKOYAMA, Y ;
SATO, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 555 (1-2) :155-162