Flow methods for the determination of polycyclic aromatic hydrocarbons using low power photomultiplier tube and charge coupled device chemiluminescence detection

被引:28
作者
Andrew, KN
Sanders, MG
Forbes, S
Worsfold, PJ
机构
[1] UNIV PLYMOUTH,DEPT ENVIRONM SCI,PLYMOUTH PL4 8AA,DEVON,ENGLAND
[2] SHELL RES LTD,THORNTON RES CTR,CHESTER CH1 3SH,CHESHIRE,ENGLAND
关键词
polycyclic aromatic hydrocarbons; chemiluminescence; charge coupled device (CCD); low power photomultiplier tube (PMT); multivariate calibration; flow injection;
D O I
10.1016/S0003-2670(97)00052-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) are produced during combustion processes (both natural and anthropogenic), and as a consequence are distributed widely throughout environmental systems. This paper describes the application of peroxyoxalate chemiluminescence (CL) detection, with a 12V low power photomultiplier tube (PMT) detector and a two-dimensional charge coupled device (CCD) detector, to the determination of PAHs. The PMT system provides comparable sensitivity to high power (1 kV) PMTs (detection limits in the pg range) and complementary information to that derived from fluorescence detection. The CCD system can be used to obtain full CL spectral information (in contrast to the integrated response from PMTs) and it has been shown that multivariate calibration can be used in conjunction with CCD detection to give good predictive errors (<9%) for simple two-component systems, e.g. benzo[k]fluoranthene and benzo[a]pyrene in hexane.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 21 条
[11]   ARYL OXALATE CHEMI-LUMINESCENCE DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IMAI, K ;
WEINBERGER, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1985, 4 (07) :170-175
[12]   PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY [J].
KWAKMAN, PJM ;
BRINKMAN, UAT .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :175-192
[13]  
Miller J.C., 1993, Statistics for Analytical Chemistry, V3rd
[14]   Scientifically operated CCD-based spectroscopic system for high-precision spectrometric determinations of seawater [J].
Pomeroy, RS ;
Baker, ME ;
Denton, MB ;
Dickson, AG .
APPLIED SPECTROSCOPY, 1995, 49 (12) :1729-1736
[15]   DETERMINATION OF HYDROGEN-PEROXIDE IN SEA-WATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
PRICE, D ;
WORSFOLD, PJ ;
MANTOURA, RFC .
ANALYTICA CHIMICA ACTA, 1994, 298 (01) :121-128
[16]   ANALYTICAL APPLICATIONS OF LIQUID-PHASE CHEMILUMINESCENCE [J].
ROBARDS, K ;
WORSFOLD, PJ .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :147-173
[17]   PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN LIQUID-CHROMATOGRAPHY [J].
SIGVARDSON, KW ;
BIRKS, JW .
ANALYTICAL CHEMISTRY, 1983, 55 (03) :432-435
[18]   PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION OF POLYCYCLIC AROMATIC-AMINES IN LIQUID-CHROMATOGRAPHY [J].
SIGVARDSON, KW ;
KENNISH, JM ;
BIRKS, JW .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :1096-1102
[19]  
*STAND COMM AN DOE, 1985, DET 6 SPEC POL AR HY
[20]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS BY LIQUID-CHROMATOGRAPHY [J].
WISE, SA ;
SANDER, LC ;
MAY, WE .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :329-349