An overview of some recent developments in ionization methods for mass spectrometry

被引:25
作者
Van Berkel, GJ [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Organ & Biol Mass Spectrometry Grp, Oak Ridge, TN 37831 USA
关键词
overview; ionization; mass spectrometry; El; CI; APCI; APPI; MALDI; ES;
D O I
10.1255/ejms.586
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An overview of some recent advances in ionization sources for mass spectrometry is presented. Limitations were set so that the overview covers ionization techniques relevant to organic and biological analysis that have appeared in the literature since the year 2000. No effort is made to be comprehensive. Rather, a broad sweep overview of author-subjective highlights among a wide variety of sources is presented. These ionization sources include electron ionization, chemical ionization, various atmospheric plasma ionization sources, laser desorption sources, sonic spray and electrospray ionization sources.
引用
收藏
页码:539 / 562
页数:24
相关论文
共 110 条
[21]  
de la Mora JF, 2000, J MASS SPECTROM, V35, P939
[22]   Chip-MS: Coupling the large with the small [J].
de Mello, AJ .
LAB ON A CHIP, 2001, 1 (01) :7N-12N
[23]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[24]   On-line electrochemistry - MS and related techniques [J].
Diehl, G ;
Karst, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :390-398
[25]   Recent developments in atmospheric pressure MALDI mass spectrometry [J].
Doroshenko, VM ;
Laiko, VV ;
Taranenko, NI ;
Berkout, VD ;
Lee, HS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (01) :39-58
[26]   High pressure ion source combined with an in axis ion trap mass spectrometer. 2. Application of selective low pressure negative ion chemical ionization [J].
Faye, T ;
Mathurin, JC ;
Brunet, A ;
Tabet, JC .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :5063-5069
[27]   Cold cathode field emitter array on a quadrupole mass spectrometer: Route to miniaturization [J].
Felter, TE .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1999, 17 (05) :1993-1996
[28]  
Foret F, 2002, PROTEOMICS, V2, P360, DOI 10.1002/1615-9861(200204)2:4<360::AID-PROT360>3.0.CO
[29]  
2-Y
[30]   Combined electrospray ionization-atmospheric pressure chemical ionization source for use in high-throughput LC-MS applications [J].
Gallagher, RT ;
Balogh, MP ;
Davey, P ;
Jackson, MR ;
Sinclair, I ;
Southern, LJ .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :973-977