Design of luminescent biochips based on enzyme, antibody, or DNA composite layers

被引:24
作者
Marquette, CA [1 ]
Thomas, D [1 ]
Degiuli, A [1 ]
Blum, LJ [1 ]
机构
[1] Univ Lyon 1, Lab Genie Enzymat & Biomol, CNRS, UMR 5013, F-69622 Villeurbanne, France
关键词
biochip; chemiluminescence; DNA array; electrochemiluminescence; enzyme array; photopolymer; protein array;
D O I
10.1007/s00216-003-2112-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of beads bearing bioactive molecules to develop generic biochips based on chemi- and electro-chemiluminescent detection was evaluated. The biochips were composed of arrayed biosensors, including enzyme-charged beads, antigen-charged beads, or oligonucleotide-charged beads, entrapped in poly( vinyl alcohol) (PVA-SbQ) photopolymer. In each case the sensing layers were spotted at the surface of a glassy carbon electrode as 0.3 muL drops, generating 500 - 800 mum spots. The luminescent reactions were either catalysed by horseradish peroxidase or triggered by application of a + 850 mV potential between the glassy carbon electrode and a platinum pseudo-reference. Enzyme biochips were designed for the concomitant detection of choline, glucose, glutamate, lactate, lysine, and urate, based on the corresponding oxidase-charged beads and the electro-chemiluminescent (ECL) reaction with luminol-immobilised beads of the hydrogen peroxide produced. Limits of detection of 1 mumol L-1 for glutamate, lysine and uric acid, 20 mumol L-1 for glucose, and 2 mumol L-1 for choline and lactate were found with detection ranging over three decades at least. Use of the electro-chemiluminescent biochip was extended to a tri-enzymatic sensing layer based on kinase-oxidase activity for detection of acetate. A reaction sequence using acetate kinase, pyruvate kinase, and pyruvate oxidase enabled the production of H2O2 in response to acetate injection in the range 10 mumol L-1 to 100 mmol L-1. Based on IgG-bearing beads, a chemiluminescent immuno-biochip has been also realised for the model detection of human IgG. Biotin-labelled anti-human IgG were used in a competitive assay, in conjunction with peroxidase-labelled streptavidin. Free antigen could then be detected with a detection limit of 25 pg (10(8) molecules) and up to 15 ng. In a similar way, the use of oligonucleotide-immobilised beads enabled the realisation of DNA-sensitive biochips which could be used to detect a biotin-labelled sequence al a level of 5 x 10(8) molecules.
引用
收藏
页码:922 / 928
页数:7
相关论文
共 18 条
[1]   ONLINE DETERMINATION OF ACETIC-ACID IN A CONTINUOUS PRODUCTION OF ACETOBACTER-ACETICUS [J].
BECKER, T ;
KITTSTEINEREBERLE, R ;
LUCK, T ;
SCHMIDT, HL .
JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) :267-275
[2]  
Blum L.J., 1997, BIOCHEMILUMINESCENT
[3]   High-density fiber-optic genosensor microsphere array capable of zeptomole detection limits [J].
Epstein, JR ;
Lee, M ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1836-1840
[4]  
FRIDOVIC.I, 1965, J BIOL CHEM, V240, P2491
[5]   Chemiluminometric sensor for simultaneous determination of L-glutamate and L-lysine with immobilized oxidases in a flow injection system [J].
Kiba, N ;
Miwa, T ;
Tachibana, M ;
Tani, K ;
Koizumi, H .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1269-1274
[6]   Genomic analysis [J].
Lee, PS ;
Lee, KH .
CURRENT OPINION IN BIOTECHNOLOGY, 2000, 11 (02) :171-175
[7]   Luminol electrochemiluminescence-based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples [J].
Marquette, CA ;
Blum, LJ .
ANALYTICA CHIMICA ACTA, 1999, 381 (01) :1-10
[8]   Semi-automated membrane based chemiluminescent immunosensor for flow injection analysis of okadaic acid in mussels [J].
Marquette, CA ;
Coulet, PR ;
Blum, LJ .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :173-182
[9]   Regenerable immunobiosensor for the chemiluminescent flow injection analysis of the herbicide 2,4-D [J].
Marquette, CA ;
Blum, LJ .
TALANTA, 2000, 51 (02) :395-401
[10]  
MARQUETTE CA, 2002, SENSOR ACTUAT B-CHEM, V90, P112