Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions

被引:122
作者
Salas-Solano, O
Carrilho, E
Kotler, L
Miller, AW
Goetzinger, W
Sosic, Z
Karger, BL [1 ]
机构
[1] Northeastern Univ, Barnett Inst, Boston, MA 02115 USA
[2] Northeastern Univ, Dept Chem, Boston, MA 02115 USA
关键词
D O I
10.1021/ac980457f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Long, accurate reads are an important factor for high-throughput de novo DNA sequencing. In previous work from this laboratory, a separation matrix of high-weight-average molecular mass (HMM) linear polyacrylamide (LPA) at a concentration of 2% (w/w) was used to separate 1000 bases of DNA sequence in 80 min with an accuracy close to 97% (Carrilho, E.; et al. Anal. Chem. 1996, 68, 3305-3313). In the present work,significantly improved speed and sequencing accuracy have been achieved by further optimization of factors affecting electrophoretic separation and data processing. A replaceable matrix containing a mixture of 2.0% (w/w) HMM (9 MDa) and 0.5% (w/w) low-weight-average molecular mass (50 kDa) LPA was employed to enhance the separation of DNA sequencing fragments in CE, Experimental conditions, such as electric field strength and column temperature, as well as internal diameter of the capillary column, have been optimized for this mixed separation matrix. Under these conditions, in combination with energy-transfer (BigDye) dye-labeled primers for high signal-to-noise ratio and a newly developed expert system for base calling, the electrophoretic separation of 1000 DNA sequencing fragments of both standard (M13mp18) and cloned single-stranded templates from human chromosome 17 could be routinely achieved in less than 55 min, with a base-calling accuracy between 98 and 99%. Identical read length, accuracy, and migration time were achieved in more than 300 consecutive runs in a single column.
引用
收藏
页码:3996 / 4003
页数:8
相关论文
共 47 条
[1]   A capillary array gel electrophoresis system using multiple laser focusing for DNA sequencing [J].
Anazawa, T ;
Takahashi, S ;
Kambara, H .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2699-2704
[2]   The effects of polymer properties on DNA separations by capillary electrophoresis in uncross-linked polymer solutions [J].
Barron, AE ;
Sunada, WM ;
Blanch, HW .
ELECTROPHORESIS, 1996, 17 (04) :744-757
[3]   A TRANSIENT ENTANGLEMENT COUPLING MECHANISM FOR DNA SEPARATION BY CAPILLARY ELECTROPHORESIS IN ULTRADILUTE POLYMER-SOLUTIONS [J].
BARRON, AE ;
BLANCH, HW ;
SOANE, DS .
ELECTROPHORESIS, 1994, 15 (05) :597-615
[4]  
Bashkin J, 1996, APPL THEOR ELECTROPH, V6, P23
[5]  
Bashkin JS, 1996, J CAPILLARY ELECTROP, V3, P61
[6]   A graph theoretic approach to the analysis of DNA sequencing data [J].
Berno, AJ .
GENOME RESEARCH, 1996, 6 (02) :80-91
[7]  
Brady D., unpublished
[8]   Factors to be considered for robust high-throughput automated DNA sequencing using a multiple-capillary array instrument [J].
Carrilho, E ;
Miller, AW ;
RuizMartinez, MC ;
Kotler, L ;
Kesilman, J ;
Karger, BL .
ULTRASENSITIVE BIOCHEMICAL DIAGNOSTICS II, PROCEEDINGS OF, 1997, 2985 :4-18
[9]   Separations of DNA fragments by capillary electrophoresis in N-substituted polyacrylamides [J].
Chiari, M ;
Riva, S ;
Gelain, A ;
Vitale, A ;
Turati, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) :347-355
[10]  
DALY MJ, 1996, TROUT SIGNAL PROCESS