Analysis of the high-frequency response of atomic force microscope cantilevers

被引:125
作者
Rabe, U [1 ]
Turner, J [1 ]
Arnold, W [1 ]
机构
[1] Univ Saarbrucken, Fraunhofer Inst Zerstorungsfreie Prufverfahren, D-66123 Saarbrucken, Germany
来源
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING | 1998年 / 66卷 / Suppl 1期
关键词
D O I
10.1007/s003390051145
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In most commercial atomic force microscopes, dynamic modes are now available as standard operation modes. Acoustical vibrations of atomic force microscope cantilevers can be excited either by insonification of the sample or by vibration of the clamped cantilever end. The resulting dynamical system is complex and highly nonlinear. Simplification of this problem is often realized by modeling the cantilever as a one-degree-of-freedom system such that the higher-order flexural modes are neglected. This point-mass model has been successful in advancing material property measurement techniques. The limits and validity of such an approximation have not been fully addressed. In this paper, the flexural beam equation is examined and compared with the point-mass model by using analytical and finite difference numerical techniques. The two systems are shown to have differences in drive-point impedance and are influenced differently by the surface damping and the contact stiffness. The angular deflection at the end of the beam and the influence of lateral sensor tip motion are considered. It is shown that the higher modes must be included for excitations above the first resonance if both the low- and the high-frequency dynamics are to be modeled accurately.
引用
收藏
页码:S277 / S282
页数:6
相关论文
共 17 条
  • [1] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [2] SCANNING MICRODEFORMATION MICROSCOPY
    CRETIN, B
    STHAL, F
    [J]. APPLIED PHYSICS LETTERS, 1993, 62 (08) : 829 - 831
  • [3] ELINGS VB, 1993, Patent No. 5266801
  • [4] Theoretical description of the transfer of vibrations from a sample to the cantilever of an atomic force microscope
    Hirsekorn, S
    Rabe, U
    Arnold, W
    [J]. NANOTECHNOLOGY, 1997, 8 (02) : 57 - 66
  • [5] Johnson K. L., 1987, CONTACT MECH
  • [6] Maivald P., 1991, Nanotechnology, V2, P103, DOI 10.1088/0957-4484/2/2/004
  • [7] Force modulation with a scanning force microscope: an analysis
    Mazeran, Pierre-Emmanuel
    Loubet, Jean-Luc
    [J]. TRIBOLOGY LETTERS, 1997, 3 (01) : 125 - 132
  • [8] MCCLELLAND GM, 1987, REV PROGR QUANTITA B, V6, P1307
  • [9] ACOUSTIC MICROSCOPY BY ATOMIC-FORCE MICROSCOPY
    RABE, U
    ARNOLD, W
    [J]. APPLIED PHYSICS LETTERS, 1994, 64 (12) : 1493 - 1495
  • [10] Vibrations of free and surface-coupled atomic force microscope cantilevers: Theory and experiment
    Rabe, U
    Janser, K
    Arnold, W
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (09) : 3281 - 3293