Monitoring ethylene content in heterophasic copolymers by near-infrared spectroscopy - Standardisation of the calibration model

被引:49
作者
Macho, S [1 ]
Rius, A [1 ]
Callao, MP [1 ]
Larrechi, MS [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Organ Q, E-43005 Tarragona, Spain
关键词
NIR; SPC; MSPC; standardisation; SBC; PDS;
D O I
10.1016/S0003-2670(01)01281-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The concentration of ethylene in samples of heterophasic copolymers was monitored for 3 months by NIR spectroscopy and partial least-squares (PLS) multivariate calibration in an attempt to assess the validity over time of the calibration model. Assuming that the model would cease to be valid, we selected and monitored sufficient samples so as to initiate a process of standardisation. The samples were selected with the Kennard-Stone algorithm and according to the representivity of their ethylene content. The monitoring techniques were univariate (Shewhart) and multivariate, (T-2 and Q) control plots. The results show that the system was stable, until the point at which there was a cause in variation which gave rise to an erroneous prediction of the ethylene content. This change did not vary over time. We used two techniques to standardise, the calibration model: slope bias correction (SBC) and piecewise direct standardisation (PDS). They both corrected the error detected. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 22 条
[1]  
AALJOKI K, 1994, PROCESS CONTR QUAL, V6, P125
[2]   Standardisation of near-infrared spectrometric instruments: A review [J].
Bouveresse, E ;
Massart, DL .
VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) :3-15
[3]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[4]   Assessing the validity of near-infrared monochromator calibrations over time [J].
Bouveresse, E ;
Casolino, C ;
Massart, DL .
APPLIED SPECTROSCOPY, 1998, 52 (04) :604-612
[5]   Infrared spectroscopy: Instrumental factors affecting the long-term validity of chemometric models [J].
Defernez, M ;
Wilson, RH .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1288-1294
[6]   Transfer of calibration in near-infrared reflectance spectrometry [J].
Dreassi, E ;
Ceramelli, G ;
Perruccio, PL ;
Corti, P .
ANALYST, 1998, 123 (06) :1259-1264
[7]  
Forina M, 1999, QUIM ANAL, V18, P49
[8]   CONTROL PROCEDURES FOR RESIDUALS ASSOCIATED WITH PRINCIPAL COMPONENT ANALYSIS [J].
JACKSON, JE ;
MUDHOLKAR, GS .
TECHNOMETRICS, 1979, 21 (03) :341-349
[9]   COMPUTER AIDED DESIGN OF EXPERIMENTS [J].
KENNARD, RW ;
STONE, LA .
TECHNOMETRICS, 1969, 11 (01) :137-&
[10]   Multivariate SPC methods for process and product monitoring [J].
Kourti, T ;
MacGregor, JF .
JOURNAL OF QUALITY TECHNOLOGY, 1996, 28 (04) :409-428