Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100 kVp

被引:105
作者
Haubenreisser, Holger [1 ]
Meyer, Mathias [1 ]
Sudarski, Sonja [1 ]
Allmendinger, Thomas [2 ]
Schoenberg, Stefan O. [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] CT Div, Siemens Healthcare Sect, Forchheim, Germany
关键词
CT; Chest; Iterative reconstruction; Spectral shaping; ITERATIVE RECONSTRUCTION TECHNIQUE; DOSE COMPUTED-TOMOGRAPHY; BACK-PROJECTION; ANGIOGRAPHY; RADIATION; MODEL;
D O I
10.1016/j.ejrad.2015.04.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objective: To prospectively investigate image quality and radiation dose of 100 kVp spectral shaping chest CT using a dedicated tin filter on a 3rd generation dual-source CT (DSCT) in comparison to standard 100 kVp chest CT. Methods: Sixty patients referred for a non-contrast chest on a 3rd generation DSCT were prospectively included and examined at 100 kVp with a dedicated tin filter. These patients were retrospectively matched with patients that were examined on a 2nd generation DSCT at 100 kVp without tin filter. Objective and subjective image quality was assessed in various anatomic regions and radiation dose was compared. Results: Radiation dose was decreased by 90% using the tin filter (3.0 vs 0.32 mSv). Soft tissue attenuation and image noise was not statistically different for both examination techniques (p > 0.05), however image noise was found to be significantly higher in the trachea when using the additional tin filter (p = 0.002). SNR was found to be statistically similar in pulmonary tissue, significantly lower when measured in air and significantly higher in the aorta for the scans on the 3rd generation DSCT. Subjective image quality with regard to overall quality and image noise and sharpness was not statistically significantly different (p > 0.05). Conclusion: 100 kVp spectral shaping chest CT by means of a tube-based tin-filter on a 3rd generation DSCT allows 90% dose reduction when compared to 100 kVp chest CT on a 2nd generation DSCT without spectral shaping. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1608 / 1613
页数:6
相关论文
共 30 条
[1]
Long-term follow-up CT scan evaluation in patients with pulmonary sarcoidosis [J].
Akira, M ;
Kozuka, T ;
Inoue, Y ;
Sakatani, M .
CHEST, 2005, 127 (01) :185-191
[2]
[Anonymous], 2014, ULTRALOW DOSE CHEST
[3]
The radiologist's conundrum: benefits and costs of increasing CT capacity and utilization - Opinion [J].
Boland, Giles W. L. ;
Guimaraes, Alexander S. ;
Mueller, Peter R. .
EUROPEAN RADIOLOGY, 2009, 19 (01) :9-11
[4]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]
Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[6]
Image Quality Improvement Using an Image-Based Noise Reduction Algorithm: Initial Experience in a Phantom Model for Urinary Stones [J].
Demehri, Shadpour ;
Salazar, Pascal ;
Steigner, Michael L. ;
Atev, Stefan ;
Masoud, Osama ;
Raffy, Philippe ;
Jacobs, Scott A. ;
Rybicki, Frank J. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) :610-615
[7]
The National Lung Screening Trial: Overview and Study Design [J].
Gatsonis, Constantine A. .
RADIOLOGY, 2011, 258 (01) :243-253
[8]
Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Kamath, RS ;
Halpern, EF ;
Saini, S .
RADIOLOGY, 2004, 232 (02) :347-353
[9]
Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Yasaka, Koichiro ;
Hanaoka, Shohei ;
Akai, Hiroyuki ;
Sato, Jiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
INVESTIGATIVE RADIOLOGY, 2013, 48 (04) :206-212
[10]
Dual-Energy CT with Single- and Dual-Source Scanners: Current Applications in Evaluating the Genitourinary Tract [J].
Kaza, Ravi K. ;
Platt, Joel F. ;
Cohan, Richard H. ;
Caoili, Elaine M. ;
Al-Hawary, Mahmoud M. ;
Wasnik, Ashish .
RADIOGRAPHICS, 2012, 32 (02) :353-369