Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis

被引:138
作者
Kalra, MK
Maher, MM
Toth, TL
Kamath, RS
Halpern, EF
Saini, S
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] GE Med Syst, Waukesha, WI USA
关键词
abdomen; CT; computed tomography (CT); radiation exposure; thin section; pelvis;
D O I
10.1148/radiol.2322031304
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare image quality, diagnostic acceptability, and radiation exposure associated with 16-section multi-detector row computed tomographic (CT) examinations of abdomen and pelvis performed with z-axis modulation technique of automatic tube current modulation and with manual selection of fixed tube current. MATERIALS AND METHODS: Sixty-two consecutive subjects (mean age, 60 years; age range, 19-84 years; male-to-female ratio, 35:27) underwent follow-up CT of abdomen and pelvis with use of a 16-section multi-detector row scanner and z-axis modulation technique (10.5-12.0-HU noise index, 10-380 mA). Scanning parameters included 140 kVp, 0.5-1.0-second gantry rotation time, 0.938:1 beam pitch, and 5-mm reconstructed section thickness. For each subject, images obtained with z-axis modulation were compared with previous images obtained with fixed tube current (200-300 mA) and with other parameters identical. Images were compared for noise and diagnostic acceptability by two subspecialty radiologists using a five-point scale (1, unacceptable; 3, acceptable; 5, excellent) at five levels: upper liver at diaphragm, porta hepatis, right kidney hilum, iliac crest, and upper margin of acetabulum. Tube current and gantry rotation time used for acquisitions at these levels were recorded. Data were analyzed with parametric and nonparametric statistical tests. RESULTS: Although no significant differences were found (P = .34), images acquired with z-axis modulation at the levels of the upper liver (diaphragm) and acetabulum had a higher noise and lower diagnostic quality, compared with images acquired with fixed tube current. Compared with fixed tube current, z-axis modulation resulted in tube current-time product reduction in 54 (87%) of 62 examinations (mean reduction, 71.2 mAs) and increase in eight (13%) (mean increase, 17.0 mAs). CONCLUSION: Compared with manually selected fixed tube current, z-axis automatic tube current modulation resulted in reduced tube current-time product and similar image noise and diagnostic acceptability at CT of abdomen and pelvis. (C) RSNA, 2004.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 13 条
  • [1] The Smart-Scan-Technique in spiral computed tomography. A new method for dose reduction.
    Giacomuzzi, SM
    Erckert, B
    Schopf, T
    Freund, MC
    Springer, P
    Dessl, A
    Jaschke, W
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (01): : 10 - 16
  • [2] Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
    Greess, H
    Nömayr, A
    Wolf, H
    Baum, U
    Lell, M
    Böwing, B
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (06) : 1571 - 1576
  • [3] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    Greess, H
    Wolf, H
    Baum, U
    Lell, M
    Pirkl, M
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (02) : 391 - 394
  • [4] Dose reduction in spiral CT:: Detection of pulmonary nodules with and without anatomic adaptation of tube current.
    Greess, H
    Baum, U
    Wolf, H
    Lell, M
    Nömayr, A
    Schmidt, B
    Kalender, WA
    Bautz, W
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05): : 466 - 470
  • [5] Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
  • [6] Greess HR, 2002, RADIOLOGY, V225, P593
  • [7] Horiuchi T., 2002, JPN SOC RADIOL TECH, V78, P166
  • [8] Strategies for CT radiation dose optimization
    Kalra, MK
    Maher, MM
    Toth, TL
    Hamberg, LM
    Blake, MA
    Shephard, JA
    Saini, S
    [J]. RADIOLOGY, 2004, 230 (03) : 619 - 628
  • [9] Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality
    Kalra, MK
    Prasad, S
    Saini, S
    Blake, MA
    Varghese, J
    Halpern, EF
    Thrall, JH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) : 1101 - 1106
  • [10] ANATOMICALLY ADAPTED VARIATION OF THE TUBE CURRENT IN CT - STUDIES ON REDUCTION OF RADIATION-DOSE AND IMAGE QUALITY
    KOPKA, L
    FUNKE, M
    BREITER, N
    HERMANN, KP
    VOSSHENRICH, R
    GRABBE, E
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 163 (05): : 383 - 387