ANATOMICALLY ADAPTED VARIATION OF THE TUBE CURRENT IN CT - STUDIES ON REDUCTION OF RADIATION-DOSE AND IMAGE QUALITY

被引:49
作者
KOPKA, L [1 ]
FUNKE, M [1 ]
BREITER, N [1 ]
HERMANN, KP [1 ]
VOSSHENRICH, R [1 ]
GRABBE, E [1 ]
机构
[1] KLINIKUM UNIV GOTTINGEN,MED PHYS & BIOPHYS ABT,D-37075 GOTTINGEN,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1995年 / 163卷 / 05期
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE QUALITY; DOSE; EXPOSURE TO PATIENTS;
D O I
10.1055/s-2007-1016013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the impact of a method for anatomically adapted tube current variation. The resulting CT image quality was evaluated quantitatively and qualitatively. Methods: CT scans of 100 patients were performed with a constant tube current (Group 1) and another 100 patients with an anatomically adapted tube current (Group 2). The CT tube current was varied during a 360 degrees tube rotation reflecting the measured density values extracted from two perpendicular scout views. The standard deviation of densities of defined regions was measured. The image quality was ranked (1 = non-diagnostic-5 = excellent) by three radiologists. Results: The effective tube current could be reduced by an average of 8.9% (0-20.4%). The mean tube current reduction depended on the body region: pelvis (13.2%), abdomen (8.4%) and thorax (3.3%). The image:quality was not significantly reduced in Group 2. Conclusion: The method for anatomically adapted tube current variation leads especially in the pelvis to a significant mAs reduction without considerable loss of image quality.
引用
收藏
页码:383 / 387
页数:5
相关论文
共 7 条
[1]   NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY [J].
CHESLER, DA ;
RIEDERER, SJ ;
PELC, NJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :64-74
[2]  
HAAGA JR, 1991, RADIOLOGY, V138, P449
[3]   RADIATION EXPOSURE DURING CT USING STANDARD AND SPIRAL TECHNIQUES [J].
LANGKOWSKI, JH ;
POGODA, P ;
HESS, A .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01) :3-11
[4]   GT OF THE CHEST - MINIMAL TUBE CURRENT REQUIRED FOR GOOD IMAGE QUALITY WITH THE LEAST RADIATION-DOSE [J].
MAYO, JR ;
HARTMAN, TE ;
LEE, KS ;
PRIMACK, SL ;
VEDAL, S ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) :603-607
[5]   PERFORMANCE EVALUATION AND QUALITY ASSURANCE OF COMPUTED TOMOGRAPHY SCANNERS, WITH ILLUSTRATIONS FROM EMI, ACTA, AND DELTA SCANNERS [J].
MCCULLOUGH, EC ;
PAYNE, JT ;
BAKER, HL ;
HATTERY, RR ;
SHEEDY, PF ;
STEPHENS, DH ;
GEDGAUDUS, E .
RADIOLOGY, 1976, 120 (01) :173-188
[6]   DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION [J].
NISHIZAWA, K ;
MARUYAMA, T ;
TAKAYAMA, M ;
OKADA, M ;
HACHIYA, J ;
FURUYA, Y .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757) :20-28
[7]  
ROTHENBERG LN, 1991, RADIOGRAPHICS, V12, P1225