Motion estimation for cardiac emission tomography by optical flow methods

被引:20
作者
Gilland, D. R. [1 ]
Mair, B. A. [1 ]
Parker, J. G. [1 ]
机构
[1] Univ Florida, Gainesville, FL 32605 USA
关键词
D O I
10.1088/0031-9155/53/11/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a new method for estimating the 3D, non-rigid object motion in a time sequence of images. The method is a generalization of a standard optical flow algorithm that is incorporated into a successive quadratic approximation framework. The method was evaluated for gated cardiac emission tomography using images obtained from a mathematical, 4D phantom and a physical, dynamic phantom. The results showed that the proposed method offers improved motion estimation accuracy relative to the standard optical flow method. Convergence of the proposed algorithm was evidenced with a monotonically decreasing objective function value with iteration. Practical application of the motion estimation method in cardiac emission tomography includes quantitative myocardial motion estimation and 4D, motion-compensated image reconstruction.
引用
收藏
页码:2991 / 3006
页数:16
相关论文
共 20 条
[11]  
Laading JK, 1999, LECT NOTES COMPUT SC, V1613, P266
[12]   Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT [J].
Lalush, DS ;
Tsui, BMW .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :875-886
[13]   A MONTE-CARLO PROGRAM FOR THE SIMULATION OF SCINTILLATION CAMERA CHARACTERISTICS [J].
LJUNGBERG, M ;
STRAND, SE .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1989, 29 (04) :257-272
[14]  
Maintz J B, 1998, Med Image Anal, V2, P1, DOI 10.1016/S1361-8415(01)80026-8
[15]   Estimation of images and nonrigid deformations in gated emission CT [J].
Mair, B. A. ;
Gilland, David R. ;
Sun, Jing .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (09) :1130-1144
[16]   A review of cardiac image registration methods [J].
Mäkelä, T ;
Clarysse, P ;
Sipilä, O ;
Pauna, N ;
Pham, QC ;
Katila, T ;
Magnin, IE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1011-1021
[17]   Nonrigid registration using free-form deformations: Application to breast MR images [J].
Rueckert, D ;
Sonoda, LI ;
Hayes, C ;
Hill, DLG ;
Leach, MO ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) :712-721
[18]   A realistic spline-based dynamic heart phantom [J].
Segars, WP ;
Lalush, DS ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :503-506
[19]   COMPUTATION OF 3-D VELOCITY-FIELDS FROM 3-D CINE CT IMAGES OF A HUMAN HEART [J].
SONG, SM ;
LEAHY, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :295-306
[20]   Alignment of dynamic cardiac PET images for correction of motion [J].
Turkington, TG ;
DeGrado, TR ;
Hanson, MW ;
Coleman, RE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (02) :235-242