Experimental assay of a Dual Mesh(R) polytetrafluoroethylene prosthesis (non-porous on one side) in the repair of abdominal wall defects

被引:29
作者
Bellon, JM
Contreras, LA
Bujan, J
Martin, ACS
机构
[1] Department of Morphological Sciences, Faculty of Medicine, Univ. of Alcalá de Henares, 28871 Alcala de Henares, Madrid
关键词
polytetrafluoroethylene prosthesis; abdominal wall defects; macrophages; abdominal wall repair;
D O I
10.1016/S0142-9612(96)00080-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The porosity of the prosthetic biomaterials used to repair defects in the abdominal wall seems to influence the tissue repair process insofar as tissue integration of the prosthetic material and the formation of adhesions with abdominal viscera are concerned. We studied the behaviour of a new type of polytetrafluoroethylene prosthesis used for the repair of abdominal wall defects, Dual Mesh(R) (DM), which has two different faces; one face has a porosity between 30 and 60 mu m, while the other is nonporous. In 20 New Zealand White rabbits, a full-thickness (except skin) 7 cm x 5 cm defect was created in the anterior abdominal wall that was repaired with DM. At 14, 30, 60 and 90 days, samples were obtained and studied by light and scanning electron microscopy. An immunohistochemical study was made with antibody anti-rabbit macrophages (RAM-11). Tensile strength was measured with an Instron tensiometer using 2-cm-wide strips obtained parallel to the shorter axis of the implant. DM induced little tissue adhesion to the material on the visceral peritoneum interface and was surrounded by organized repair tissue. The biomaterial was integrated in the repair tissue on the subcutaneous interface, but not on the peritoneal interface. The macrophage response decreased between days 14 and 90 (P < 0.001). Tensile strength increased significantly (P < 0.05) at every study period. We conclude that the DM prosthesis has little tendency to formation of visceral adhesions, the DM prosthesis was well tolerated by the receptor organism and the tensile strength of the prosthesis/receptor tissue interface increased with time. (C) 1996 Elsevier Science Limited
引用
收藏
页码:2367 / 2372
页数:6
相关论文
共 21 条
[1]   EXPERIMENTAL EVALUATION OF A NEW COMPOSITE MESH WITH THE SELECTIVE PROPERTY OF INCORPORATION TO THE ABDOMINAL-WALL WITHOUT ADHERING TO THE INTESTINES [J].
AMID, PK ;
SHULMAN, AG ;
LICHTENSTEIN, IL ;
SOSTRIN, S ;
YOUNG, J ;
HAKAKHA, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (03) :373-375
[2]  
BELLON J, 1995, EUR SURG RES S1, V27, P11
[3]   INTEGRATION OF BIOMATERIALS IMPLANTED INTO ABDOMINAL-WALL - PROCESS OF SCAR FORMATION AND MACROPHAGE RESPONSE [J].
BELLON, JM ;
BUJAN, J ;
CONTRERAS, L ;
HERNANDO, A .
BIOMATERIALS, 1995, 16 (05) :381-387
[4]   MACROPHAGE RESPONSE TO EXPERIMENTAL IMPLANTATION OF POLYPROPYLENE PROSTHESES [J].
BELLON, JM ;
BUJAN, J ;
CONTRERAS, L ;
HERNANDO, A ;
JURADO, F .
EUROPEAN SURGICAL RESEARCH, 1994, 26 (01) :46-53
[5]  
BELLON JM, 1994, SOC ITALIANO FISIOPA, P85
[6]  
BELLON JM, 1994, BRIT J SURG, V81, P69
[7]  
BJURSTEN LM, 1991, 9 EUR C BIOM CHEST S
[8]  
BLEICHRODT RP, 1993, SURG GYNECOL OBSTET, V176, P18
[9]  
CONTRERAS L, 1995, BRIT J SURG, V82, P55
[10]  
CONTRERAS LA, 1996, EUR SURG RES S1, V28, P45