Serial intravascular ultrasound of intracoronary γ-radiation assessment of the efficacy therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions

被引:25
作者
Ahmed, JM
Mintz, GS
Waksman, R
Mehran, R
Leiboff, B
Pichard, AD
Satler, LF
Kent, KM
Weissman, NJ
机构
[1] Washington Hosp Ctr, Inst Cardiovasc Res, Intravasc Ultrasound Imaging & Cardiac Catheteriz, Washington, DC 20010 USA
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
ultrasonics; restenosis; radiotherapy;
D O I
10.1161/hc3301.095285
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The efficacy of coronary gamma -irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. Methods and Results-We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm.) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma -irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P = 0.0064 and P = 0.0125 respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0 +/- 1.4 mm); areas were 2.9 +/- 1.0 mm(2) in irradiated patients in Long WRIST and 1.9 +/- 1.1 mm(2) in placebo patients in Long WRIST (P < 0.005 for all comparisons). Conclusions-Serial IVUS analysis shows that gamma -irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.
引用
收藏
页码:856 / 859
页数:4
相关论文
共 16 条
[1]  
Ahmed JM, 2001, CIRCULATION, V103, P188
[2]  
Amant C, 1997, CIRCULATION, V96, P56
[3]   In-stent restenosis: Long-term outcome and predictors of subsequent target lesion revascularization after repeat balloon angioplasty [J].
Bossi, I ;
Klersy, C ;
Black, AJ ;
Cortina, R ;
Choussat, R ;
Cassagneau, B ;
Jordan, C ;
Laborde, JC ;
Laurent, JP ;
Bernies, M ;
Fajadet, J ;
Marco, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1569-1576
[4]   Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis [J].
Dauerman, HL ;
Baim, DS ;
Cutlip, D ;
Sparano, AM ;
Gibson, CM ;
Kuntz, RE ;
Carrozza, JP ;
Garber, GR ;
Cohen, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :277-284
[5]   SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS [J].
DUSSAILLANT, GR ;
MINTZ, GS ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
POPMA, JJ ;
WONG, SC ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :720-724
[6]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[7]  
Kornowski R, 1997, CIRCULATION, V95, P1366
[8]   Immediate and long-term outcomes of rotational atherectomy versus balloon angioplasty alone for treatment of diffuse in-stent restenosis [J].
Lee, SG ;
Lee, CW ;
Cheong, SS ;
Hong, MK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (02) :140-143
[9]   Angiographic patterns of in-stent restenosis - Classification and implications for long-term outcome [J].
Mehran, R ;
Dangas, G ;
Abizaid, AS ;
Mintz, GS ;
Lansky, AJ ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Stone, GW ;
Leon, MB .
CIRCULATION, 1999, 100 (18) :1872-1878
[10]  
Mehran R, 1997, CIRCULATION, V96, P2183