Serial intravascular ultrasound of intracoronary γ-radiation assessment of the efficacy therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions

被引:25
作者
Ahmed, JM
Mintz, GS
Waksman, R
Mehran, R
Leiboff, B
Pichard, AD
Satler, LF
Kent, KM
Weissman, NJ
机构
[1] Washington Hosp Ctr, Inst Cardiovasc Res, Intravasc Ultrasound Imaging & Cardiac Catheteriz, Washington, DC 20010 USA
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
ultrasonics; restenosis; radiotherapy;
D O I
10.1161/hc3301.095285
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The efficacy of coronary gamma -irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. Methods and Results-We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm.) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma -irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P = 0.0064 and P = 0.0125 respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0 +/- 1.4 mm); areas were 2.9 +/- 1.0 mm(2) in irradiated patients in Long WRIST and 1.9 +/- 1.1 mm(2) in placebo patients in Long WRIST (P < 0.005 for all comparisons). Conclusions-Serial IVUS analysis shows that gamma -irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.
引用
收藏
页码:856 / 859
页数:4
相关论文
共 16 条
[11]  
Mintz GS, 2000, CIRCULATION, V102, P2915
[12]   Long-term clinical follow-up after successful repeat percutaneous intervention for stent restenosis [J].
Reimers, B ;
Moussa, I ;
Akiyama, T ;
Tucci, G ;
Ferraro, M ;
Martini, G ;
Blengino, S ;
DiMario, C ;
Colombo, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) :186-192
[13]   Residual plaque burden, delivered dose, and tissue composition predict 6-month outcome after balloon angioplasty and β-radiation therapy [J].
Sabaté, M ;
Marijnissen, JPA ;
Carlier, SG ;
Kay, IP ;
van der Giessen, WJ ;
Coen, VLMA ;
Ligthart, JMR ;
Boersma, E ;
Costa, MA ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 101 (21) :2472-2477
[14]   A subgroup analysis of the scripps coronary radiation to inhibit proliferation poststenting trial [J].
Teirstein, PS ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Mintz, GS ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Cloutier, DA ;
Leon, MB ;
Tripuraneni, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (05) :1097-1104
[15]   Catheter-based radiotherapy to inhibit restenosis after coronary stenting [J].
Teirstein, PS ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Mintz, GS ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Morris, NB ;
Leon, MB ;
Tripuraneni, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24) :1697-1703
[16]   Intracoronary γ-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis [J].
Waksman, R ;
White, L ;
Chan, RC ;
Bass, BG ;
Geirlach, L ;
Mintz, GS ;
Satler, LF ;
Mehran, R ;
Serruys, PW ;
Lansky, AJ ;
Fitzgerald, P ;
Bhargava, B ;
Kent, KM ;
Pichard, AD ;
Leon, MB .
CIRCULATION, 2000, 101 (18) :2165-2171