Electroinjection analysis. The introduction of a new variant of flow-injection analysis and comparison with electrophoretically-mediated microanalysis

被引:19
作者
Andreev, VP
Kamenev, AG
Popov, NS
机构
[1] Inst. for Analytical Instrumentation, Russian Academy of Sciences, 198103 St. Petersburg
关键词
electroinjection analysis; electrophoretically-mediated microanalysis;
D O I
10.1016/0039-9140(95)01784-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of mixing sample and reagent due to the difference in their electrophoretic mobilities is introduced. Unlike electrophoretically-mediated microanalysis, sample and reagent are injected from the opposite ends of a capillary tube. This method is compared with electrophoretically-mediated microanalysis. Experiments are performed showing the possibilities of this new method.
引用
收藏
页码:909 / 914
页数:6
相关论文
共 10 条
[1]   ON THE MATHEMATICAL-MODEL OF FLOW-INJECTION ANALYSIS .2. THE 2ND-ORDER CHEMICAL-REACTION IN A STRAIGHT TUBE [J].
ANDREEV, VP ;
KONDRATIEVA, TV .
TALANTA, 1994, 41 (10) :1755-1763
[2]   ULTRAMICRO ENZYME ASSAYS IN A CAPILLARY ELECTROPHORETIC SYSTEM [J].
BAO, JM ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :217-224
[3]   OPTIMIZATION OF CONFLUENT MIXING IN FLOW-INJECTION ANALYSIS [J].
CLARK, GD ;
HUNGERFORD, JM ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1989, 61 (09) :973-979
[4]   SELECTIVITY IN ELECTROPHORETICALLY MEDIATED MICROANALYSIS BY CONTROL OF PRODUCT DETECTION TIME [J].
HARMON, BJ ;
LEESONG, I ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3797-3805
[5]   MATHEMATICAL TREATMENT OF ELECTROPHORETICALLY MEDIATED MICROANALYSIS [J].
HARMON, BJ ;
PATTERSON, DH ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2655-2662
[6]   ELECTROPHORETICALLY MEDIATED MICROANALYSIS OF ETHANOL [J].
HARMON, BJ ;
PATTERSON, DH ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY A, 1993, 657 (02) :429-434
[7]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[8]   OPTICAL IMPROVEMENTS OF A Z-SHAPED CELL FOR HIGH-SENSITIVITY UV ABSORBENCY DETECTION IN CAPILLARY ELECTROPHORESIS [J].
MORING, SE ;
REEL, RT ;
VANSOEST, REJ .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3454-3459
[9]   A COAXIAL JET MIXER FOR RAPID KINETIC-ANALYSIS IN FLOW-INJECTION AND FLOW INJECT ION CYTOMETRY [J].
SCAMPAVIA, LD ;
BLANKENSTEIN, G ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2743-2749
[10]   NANOLITER-SCALE MULTIREFLECTION CELL FOR ABSORPTION DETECTION IN CAPILLARY ELECTROPHORESIS [J].
WANG, TS ;
AIKEN, JH ;
HUIE, CW ;
HARTWICK, RA .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1372-1376