Accuracy of electron counting using a 7-junction electron pump

被引:267
作者
Keller, MW
Martinis, JM
Zimmerman, NM
Steinbach, AH
机构
[1] NIST, GAITHERSBURG, MD 20899 USA
[2] UNIV COLORADO, BOULDER, CO 80309 USA
关键词
D O I
10.1063/1.117492
中图分类号
O59 [应用物理学];
学科分类号
摘要
We have operated a 7-junction electron pump as an electron counter with an error per pumped electron of 15 parts in 10(9) and an average hold time of 600 s. The accuracy and hold time are sufficient to enable a new fundamental standard of capacitance. We compare the measured accuracy of the pump as a function of pumping speed and temperature with theoretical predictions based on a model which includes stray capacitance. (C) 1996 American Institute of Physics.
引用
收藏
页码:1804 / 1806
页数:3
相关论文
共 9 条
[1]   OFFSET MASKS FOR LIFT-OFF PHOTOPROCESSING [J].
DOLAN, GJ .
APPLIED PHYSICS LETTERS, 1977, 31 (05) :337-339
[2]   MEASUREMENT OF SINGLE-ELECTRON LIFETIMES IN A MULTIJUNCTION TRAP [J].
DRESSELHAUS, PD ;
JI, L ;
HAN, SY ;
LUKENS, JE ;
LIKHAREV, KK .
PHYSICAL REVIEW LETTERS, 1994, 72 (20) :3226-3229
[3]  
Grabert H., 1992, Single Charge Tunneling
[4]   PERFORMANCE OF THE ELECTRON PUMP WITH STRAY CAPACITANCES [J].
JAYJENSEN, HD ;
MARTINIS, JM .
PHYSICA B, 1994, 194 (pt 1) :1255-1256
[5]   ACCURACY OF THE ELECTRON PUMP [J].
JENSEN, HD ;
MARTINIS, JM .
PHYSICAL REVIEW B, 1992, 46 (20) :13407-13427
[6]   EFFECT OF ENVIRONMENTAL NOISE ON THE ACCURACY OF COULOMB-BLOCKADE DEVICES [J].
MARTINIS, JM ;
NAHUM, M .
PHYSICAL REVIEW B, 1993, 48 (24) :18316-18319
[7]   METROLOGICAL ACCURACY OF THE ELECTRON PUMP [J].
MARTINIS, JM ;
NAHUM, M ;
JENSEN, HD .
PHYSICAL REVIEW LETTERS, 1994, 72 (06) :904-907
[8]   SINGLE-ELECTRON PUMP BASED ON CHARGING EFFECTS [J].
POTHIER, H ;
LAFARGE, P ;
URBINA, C ;
ESTEVE, D ;
DEVORET, MH .
EUROPHYSICS LETTERS, 1992, 17 (03) :249-254
[9]   MEASURING THE ELECTRONS CHARGE AND THE FINE-STRUCTURE CONSTANT BY COUNTING ELECTRONS ON A CAPACITOR [J].
WILLIAMS, ER ;
GHOSH, RN ;
MARTINIS, JM .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1992, 97 (02) :299-304