Prostatic biopsy directed with endorectal MR spectroscopic imaging findings in patients with elevated prostate specific antigen levels and prior negative biopsy findings: Early experience

被引:114
作者
Prando, A
Kurhanewicz, J
Borges, AP
Oliveira, EM
Figueiredo, E
机构
[1] Vera Cruz Hosp, Dept Radiol, BR-13013161 Campinas, SP, Brazil
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[3] GE Med Syst, MRI Adv Applicat Serv, Sao Paulo, Brazil
关键词
D O I
10.1148/radiol.2363040615
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively evaluate the accuracy of transrectal ultrasonography (US)-guided biopsy directed with magnetic resonance (MR) spectroscopic imaging in patients with an elevated prostate specific antigen (PSA) level and negative findings at prior biopsy by using subsequent biopsy results as the reference standard. MATERIALS AND METHODS: The committee on human research approved this study, and written informed consent was obtained. MR imaging and MR spectroscopic imaging were performed in 42 men (age range, 45-75 years; average age, 63.3 years; median age, 65 years) with negative findings at two or more prostatic biopsies and at digital rectal examination. MR spectroscopic data were rated on a scale of 1 (benign) to 5 (malignant) on the basis of standardized metabolic criteria. Abnormal voxels were overlaid on the corresponding transverse transrectal US images and used to perform voxel-guided biopsy of the prostate. All patients subsequently received an extended-pattern biopsy scheme. RESULTS: Thirty-one of 42 patients demonstrated metabolic abnormalities that were suspicious for cancer (voxels with scores >= 4). Eleven patients with negative MR spectroscopic imaging results also had negative biopsy findings. Cancer was detected in 17 (55%) of 31 men with positive MR spectroscopic imaging findings (voxels with scores >= 4) with a sensitivity of 100%, specificity of 44%, positive predictive value of 55%, negative predictive value of 100%, and accuracy of 67%. In men with at least one spectroscopic voxel with a score of 5 (12 of 17 men), the sensitivity, specificity, positive and negative predictive values, and accuracy were 71%, 84%, 75%, 81 %, and 79%, respectively. CONCLUSION: Metabolic data from MR spectroscopic imaging can be transferred to transrectal US images and used to sample regions of cancer in men with rising PSA levels and negative findings at prior biopsy with good accuracy.(c) RSNA, 2005.
引用
收藏
页码:903 / 910
页数:8
相关论文
共 24 条
  • [11] Males RG, 2000, MAGNET RESON MED, V43, P17, DOI 10.1002/(SICI)1522-2594(200001)43:1<17::AID-MRM3>3.0.CO
  • [12] 2-6
  • [13] Prostate biopsy: Indications and technique
    Matlaga, BR
    Eskew, LA
    McCullough, DL
    [J]. JOURNAL OF UROLOGY, 2003, 169 (01) : 12 - 19
  • [14] ZONAL DISTRIBUTION OF PROSTATIC ADENOCARCINOMA - CORRELATION WITH HISTOLOGIC PATTERN AND DIRECTION OF SPREAD
    MCNEAL, JE
    REDWINE, EA
    FREIHA, FS
    STAMEY, TA
    [J]. AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1988, 12 (12) : 897 - 906
  • [15] Prospective evaluation of endorectal magnetic resonance imaging to detect tumor foci in men with prior negative prostatic biopsy: A pilot study
    Perrotti, M
    Han, KR
    Epstein, RE
    Kennedy, EC
    Rabbani, F
    Badani, K
    Pantuck, AJ
    Weiss, RE
    Cummings, KB
    [J]. JOURNAL OF UROLOGY, 1999, 162 (04) : 1314 - 1317
  • [16] Helical CT of prostate cancer: Early clinical experience
    Prando, A
    Wallace, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 343 - 346
  • [17] Prostate cancer: Localization with three-dimensional proton MR spectroscopic imaging - Clinicopathologic study
    Scheidler, J
    Hricak, H
    Vigneron, DB
    Yu, KK
    Sokolov, DL
    Huang, LR
    Zaloudek, CJ
    Nelson, SJ
    Carroll, PR
    Kurhanewicz, J
    [J]. RADIOLOGY, 1999, 213 (02) : 473 - 480
  • [18] Dualband spectral-spatial RF pulses for prostate MR spectroscopic imaging
    Schricker, AA
    Pauly, JM
    Kurhanewicz, J
    Swanson, MG
    Vigneron, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1079 - 1087
  • [19] Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses
    StarLack, J
    Vigneron, DB
    Pauly, J
    Kurhanewicz, J
    Nelson, SJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04) : 745 - 757
  • [20] Prostate cancer diagnosis using a saturation needle biopsy technique after previous negative sextant biopsies
    Stewart, CS
    Leibovich, BC
    Weaver, AL
    Lieber, MM
    [J]. JOURNAL OF UROLOGY, 2001, 166 (01) : 86 - 91