Fast gradient elution reversed-phase high-performance liquid chromatography with diode-array detection as a high-throughput screening method for drugs of abuse - I. Chromatographic conditions

被引:27
作者
Stoll, Dwight R. [1 ]
Paek, Changyub [1 ]
Carr, Peter W. [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
gradient elution HPLC; drugs of abuse; drug screening; forensics; toxicology; high-throughput;
D O I
10.1016/j.chroma.2006.10.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new approach for the high-throughput screening of biological samples to detect the presence of regulated intoxicants has been developed by modifying a conventional gradient elution high-performance liquid chromatograph (HPLC). The goal of this work was to improve the speed of gradient elution screening methods over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which is the basis for the identification of intoxicant compounds. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between consecutive gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.80 min, including 0.30 min for column re-equilibration between analyses. Retention times of standard calibration solutes are reproducible to better than 0.002 min in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. For a set of forty-seven target compounds, the discriminating power and mean list length were found to be 0.95 and 3.26, respectively. In comparison to previous work with similar numbers of target compounds, the current approach provides an order of magnitude improvement in analysis time, and a four-fold decrease in mean list length. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 36 条
[1]  
*AM AC FOR SCI, 2002, FOR TOX LAB GUID
[2]  
BOGUSZ M, 1991, LC GC-MAG SEP SCI, V9, P290
[3]   CORRECTION OF RETENTION INDEX VALUES IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A TOOL FOR COMPARISON OF RESULTS OBTAINED WITH DIFFERENT OCTADECYL SILICA PHASES [J].
BOGUSZ, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :404-409
[4]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DATABASE OF RETENTION INDEXES AND UV SPECTRA OF TOXICOLOGICALLY RELEVANT SUBSTANCES AND ITS INTERLABORATORY USE [J].
BOGUSZ, M ;
ERKENS, M .
JOURNAL OF CHROMATOGRAPHY A, 1994, 674 (1-2) :97-126
[5]   INTERLABORATORY APPLICABILITY OF A RETENTION INDEX LIBRARY OF DRUGS FOR SCREENING BY REVERSED-PHASE HPLC IN SYSTEMATIC TOXICOLOGICAL ANALYSIS [J].
BOGUSZ, M ;
ERKENS, M ;
FRANKE, JP ;
WIJSBEEK, J ;
DEZEEUW, RA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (06) :1341-1354
[6]   Role of ion pairing in anionic additive effects on the separation of cationic drugs in reversed-phase liquid chromatography [J].
Dai, J ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (02) :169-184
[7]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[8]   DRUGS-OF-ABUSE TESTING IN URINE - STATISTICAL APPROACH AND EXPERIMENTAL COMPARISON OF IMMUNOCHEMICAL AND CHROMATOGRAPHIC TECHNIQUES [J].
FERRARA, SD ;
TEDESCHI, L ;
FRISON, G ;
BRUSINI, G ;
CASTAGNA, F ;
BERNARDELLI, B ;
SOREGAROLI, D .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (05) :278-291
[9]   RAPID, COMPREHENSIVE SCREENING-PROCEDURE FOR BASIC DRUGS IN BLOOD OR TISSUES BY GAS-CHROMATOGRAPHY [J].
FOERSTER, EH ;
HATCHETT, D ;
GARRIOTT, JC .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1978, 2 (02) :50-55
[10]   PAPER CHROMATOGRAPHIC IDENTIFICATION OF COMPOUNDS [J].
GALANOS, DS ;
KAPOULAS, VM .
JOURNAL OF CHROMATOGRAPHY, 1964, 13 (01) :128-&