Measurement of very low stable isotope enrichments by gas chromatography mass spectrometry: Application to measurement of muscle protein synthesis

被引:104
作者
Patterson, BW
Zhang, XJ
Chen, YP
Klein, S
Wolfe, RR
机构
[1] UNIV TEXAS,MED BRANCH,DEPT SURG,GALVESTON,TX 77550
[2] SHRINERS BURNS INST,METAB UNIT,GALVESTON,TX
来源
METABOLISM-CLINICAL AND EXPERIMENTAL | 1997年 / 46卷 / 08期
关键词
D O I
10.1016/S0026-0495(97)90084-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of muscle protein synthesis using stable isotopically labeled tracers usually requires isotope ratio mass spectrometry (IRMS) because of the need to measure very low enrichments of stable isotopically labeled tracers (tracer to tracee ratio [TTR], 0.005% to 0.10%). This approach is laborious, requiring purification of the metabolite of interest and combustion to a gas for IRMS analysis, and is best suited for use with C-13 tracers. We have developed an approach whereby low enrichments can be conveniently measured by a conventional gas chromatography/mass spectrometry (GC/MS) instrument. The approach includes three critical elements: (1) use of a highly substituted tracer containing three or more labeled atoms, to measure enrichment above a very low natural abundance of highly substituted isotopomers; (2) use of a highly substituted natural abundance isotopomer as a base ion for comparison rather than the most abundant m + 0 isotopomer, to reduce the dynamic range of the isotopomer ratio measurement; and (3) a sensitive mass spectrometric analysis that measures the natural abundance of the isotopomer used as a tracer with a high signal to noise ratio (> 100:1). This approach was used to measure the rate of synthesis of muscle protein following a primed continuous infusion of L-[C-13(6)]-phenylalanine (PHE) in eight fasted dogs and L-[H-2(3)]-leucine in five fasted human subjects. Values for [C-13(6)]-PHE enrichment by GC/MS rates were virtually identicalthose obtained by a conventional approach using high-performance liquid chromatography (HPLC) to isolate PHE, combustion to CO2, and measurement of (CO2)-C-13 enrichment by IRMS (IRMS enrichment = 0.9988 x GC/MS enrichment, R-2 = .891), resulting in identical values for muscle fractional synthesis rates ([FSRs] mean +/- SEM: 2.7 +/- 0.2 and 2.5 +/- 0.2%/d for GC/MS and IRMS, respectively). Human muscle synthesis rates measured by GC/MS analysis of [H-2(3)]-leucine enrichment (1.90 +/- 0.17%/d) were similar to published values based on IRMS analysis using a 1-C-13-leucine tracer. We conclude that compared with the IRMS approach, the GC/MS approach offers faster throughput, has a lower sample requirement, and is suitable for a wider variety of tracers such as H-2. The principles outlined here should be applicable to the measurement of low enrichments by GC/MS in a wide variety of stable isotope tracer applications. Copyright (C) 1997 by W.B. Saunders Company.
引用
收藏
页码:943 / 948
页数:6
相关论文
共 12 条
[1]   INTRACELLULAR FREE AMINO-ACID CONCENTRATION IN HUMAN MUSCLE-TISSUE [J].
BERGSTROM, J ;
FURST, P ;
NOREE, LO ;
VINNARS, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (06) :693-697
[2]   TRANSMEMBRANE TRANSPORT AND INTRACELLULAR KINETICS OF AMINO-ACIDS IN HUMAN SKELETAL-MUSCLE [J].
BIOLO, G ;
FLEMING, RYD ;
MAGGI, SP ;
WOLFE, RR .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 1995, 268 (01) :E75-E84
[3]  
BIOLO G, 1995, AM J PHYSIOL-ENDOC M, V268, pE514
[4]   PHYSIOLOGICAL HYPERINSULINEMIA STIMULATES PROTEIN-SYNTHESIS AND ENHANCES TRANSPORT OF SELECTED AMINO-ACIDS IN HUMAN SKELETAL-MUSCLE [J].
BIOLO, G ;
FLEMING, RYD ;
WOLFE, RR .
JOURNAL OF CLINICAL INVESTIGATION, 1995, 95 (02) :811-819
[5]   THE DETERMINATION OF LOW D(5)-PHENYLALANINE ENRICHMENT (0.002-0.09 ATOM PERCENT EXCESS), AFTER CONVERSION TO PHENYLETHYLAMINE, IN RELATION TO PROTEIN-TURNOVER STUDIES BY GAS-CHROMATOGRAPHY ELECTRON IONIZATION MASS-SPECTROMETRY [J].
CALDER, AG ;
ANDERSON, SE ;
GRANT, I ;
MCNURLAN, MA ;
GARLICK, PJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (07) :421-424
[6]   MEASUREMENT OF BIASES IN THE ELECTRON MULTIPLIER ION DETECTION SYSTEM OF A FINNIGAN-MAT MODEL 261 MASS-SPECTROMETER [J].
LOVERIDGE, WD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 74 (2-3) :197-206
[7]   SELECTED ION MONITORING MASS-SPECTROMETRY - PARAMETERS AFFECTING QUANTITATIVE-DETERMINATION [J].
LOW, IA ;
LIU, RH ;
BARKER, SA ;
FISH, F ;
SETTINE, RL ;
PIOTROWSKI, EG ;
DAMERT, WC ;
LIU, JY .
BIOMEDICAL MASS SPECTROMETRY, 1985, 12 (11) :633-637
[8]   MEASUREMENT OF N-15 ENRICHMENT IN MULTIPLE AMINO-ACIDS AND UREA IN A SINGLE ANALYSIS BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
PATTERSON, BW ;
CARRARO, F ;
WOLFE, RR .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (09) :518-523
[9]   CONCENTRATION-DEPENDENCE OF METHYL PALMITATE ISOTOPE RATIOS BY ELECTRON-IMPACT IONIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
PATTERSON, BW ;
WOLFE, RR .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (08) :481-486
[10]   PROTEIN-TURNOVER AND AMINO-ACID-METABOLISM IN HUMAN SKELETAL-MUSCLE [J].
SMITH, K ;
RENNIE, MJ .
BAILLIERES CLINICAL ENDOCRINOLOGY AND METABOLISM, 1990, 4 (03) :461-498