Detection of coronary artery stenoses with multislice helical CT angiography

被引:95
作者
Becker, CR
Knez, A
Leber, A
Treede, H
Ohnesorge, B
Schoepf, UJ
Reiser, MF
机构
[1] Univ Munich, Dept Clin Radiol, Klinkum Grosshadern, D-81377 Munich, Germany
[2] Univ Munich, Clin Internal Med, Klinkum Grosshadern, D-81377 Munich, Germany
[3] Univ Munich, Clin Cardiac Surg, Klinkum Grosshadern, D-81377 Munich, Germany
关键词
coronary arteries; coronary artery disease; computed tomography; coronary angiography;
D O I
10.1097/00004728-200209000-00015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The authors compared multislice CT angiography and selective angiography for the assessment of coronary artery disease. Methods: In 28 patients, the presence and degree of coronary artery stenoses were determined in coronary segments prepared with beta-blocker for good image quality with multislice CT. Results: In 187 coronary artery segments, sensitivity, specificity, and negative predictive value for the detection of stenoses >50% with multislice CT angiography were 81%, 90%, and 97%, respectively. The agreement for determining the degree of stenoses with multislice CT angiography and selective coronary angiography was only moderate (kappa = 0.58). Conclusions: Because of the limited spatial resolution, it is not possible with multislice CT angiography to determine the degree the coronary artery stenoses precisely. However, the high negative predictive value indicates that multislice CT may be a suitable tool to reliably rule out coronary artery disease.
引用
收藏
页码:750 / 755
页数:6
相关论文
共 28 条
  • [11] Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart
    Flohr, T
    Ohnesorge, B
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 907 - 923
  • [12] Funabashi N, 2001, CIRCULATION, V103, pE25
  • [13] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [14] Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    Kachelriess, M
    Kalender, WA
    [J]. MEDICAL PHYSICS, 1998, 25 (12) : 2417 - 2431
  • [15] Coronary calcification and coronary atherosclerosis: Site by site comparative morphologic study of electron beam computed tomography and coronary angiography
    Kajinami, K
    Seki, H
    Takekoshi, N
    Mabuchi, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (07) : 1549 - 1556
  • [16] CORONARY-ARTERY STENOSES - 3-DIMENSIONAL IMAGING WITH ELECTROCARDIOGRAPHICALLY TRIGGERED, CONTRAST AGENT-ENHANCED, ELECTRON-BEAM CT
    MOSHAGE, WEL
    ACHENBACH, S
    SEESE, B
    BACHMANN, K
    KIRCHGEORG, M
    [J]. RADIOLOGY, 1995, 196 (03) : 707 - 714
  • [17] Evaluation of corollary artery stenoses using electron-beam CT and multiplanar reformation
    Nakanishi, T
    Ito, K
    Imazu, M
    Yamakido, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) : 121 - 127
  • [18] Coronary angiography with multi-slice computed tomography
    Nieman, K
    Oudkerk, M
    Rensing, BJ
    van Ooijen, P
    Munne, A
    van Geuns, RJ
    de Feyter, PJ
    [J]. LANCET, 2001, 357 (9256) : 599 - 603
  • [19] Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience
    Ohnesorge, B
    Flohr, T
    Becker, C
    Kopp, AF
    Schoepf, UJ
    Baum, U
    Knez, A
    Klingenbeck-Regn, K
    Reiser, MF
    [J]. RADIOLOGY, 2000, 217 (02) : 564 - 571
  • [20] Coronary artery stenoses: Assessment with contrast-enhanced electron-beam CT and axial reconstructions
    Reddy, GP
    Chernoff, DM
    Adams, JR
    Higgins, CB
    [J]. RADIOLOGY, 1998, 208 (01) : 167 - 172