Multileaf collimator interleaf transmission

被引:40
作者
Balog, JP
Mackie, TR
Wenman, DL
Glass, M
Fang, G
Pearson, D
机构
[1] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
[2] Univ Wisconsin, Phys Sci Lab, Stoughton, WI 53589 USA
关键词
multileaf collimators; tongue-and-groove; tomotherapy; NOMOS; MIMiC; intensity modulation; penumbral blurring;
D O I
10.1118/1.598501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multileaf collimators (MLCs) have advanced past their original design purpose as a replacement for held shaping cerrobend blocks. Typically, MLCs incorporate an interlocking tongue-and-groove design between adjacent leaves to minimize leakage between leaves. They are beginning to be used to provide intensity modulation for conformal three-dimensional radiation therapy. It is possible that a critical target volume may receive an underdose due to the region of overlap if adjacent leaves are allowed to alternate between the open and closed positions, as they might if intensity modulation is employed. This work demonstrates the magnitude of that effect for a commercially available one-dimensional temporally modulated MLC. The magnitude of the transmission between leaves as a function of leaf separation was also studied, as well as the transmission as a function of leaf rotation away from the source. The results of this work were used for the design of a tomotherapy MLC, The radiation leakage considerations for a tomotherapy MLC are discussed. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01702-2].
引用
收藏
页码:176 / 186
页数:11
相关论文
共 19 条
[1]  
BLEIER AR, 1996, MED PHYS, V23, P1074
[2]   REALIZATION AND VERIFICATION OF 3-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH MODULATED FIELDS [J].
BORTFELD, T ;
BOYER, AL ;
SCHLEGEL, W ;
KAHLER, DL ;
WALDRON, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :899-908
[3]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[4]   DOSE CALCULATION FOR PHOTON BEAMS WITH INTENSITY MODULATION GENERATED BY DYNAMIC JAW OR MULTILEAF COLLIMATIONS [J].
CHUI, CS ;
LOSASSO, T ;
SPIROU, S .
MEDICAL PHYSICS, 1994, 21 (08) :1237-1244
[5]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[6]   CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM [J].
GALVIN, JM ;
SMITH, AR ;
LALLY, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02) :181-192
[7]   COMBINING MULTILEAF FIELDS TO MODULATE FLUENCE DISTRIBUTIONS [J].
GALVIN, JM ;
CHEN, XG ;
SMITH, RM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03) :697-705
[8]   MEASUREMENT OF THE SOURCE SIZE OF A 6-MV AND 18-MV RADIOTHERAPY LINAC [J].
LOEWENTHAL, E ;
LOEWINGER, E ;
BARAVRAHAM, E ;
BARNEA, G .
MEDICAL PHYSICS, 1992, 19 (03) :687-690
[9]   TOMOTHERAPY - OPTIMIZED PLANNING AND DELIVERY OF RADIATION-THERAPY [J].
MACKIE, TR ;
HOLMES, TW ;
RECKWERDT, PJ ;
YANG, J .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) :43-55
[10]   TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY [J].
MACKIE, TR ;
HOLMES, T ;
SWERDLOFF, S ;
RECKWERDT, P ;
DEASY, JO ;
YANG, J ;
PALIWAL, B ;
KINSELLA, T .
MEDICAL PHYSICS, 1993, 20 (06) :1709-1719