Pedicle screw fixation of the thoracic spine:: An in vitro biomechanical study on different configurations

被引:40
作者
Deviren, V
Acaroglu, E
Lee, J
Fujita, M
Hu, S
Lenke, LG
Polly, D
Kuklo, TR
O'Brien, M
Brumfield, D
Puttlitz, CM
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Orthopaed Biomech Lab, San Francisco, CA 94110 USA
[2] Washington Univ, Dept Orthopaed Surg, St Louis, MO 63130 USA
[3] Univ Minnesota, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
[4] Walter Reed Army Med Ctr, Dept Orthopaed Surg, Washington, DC 20307 USA
[5] Miami Childrens Hosp, Dept Orthopaed Surg, Miami, FL USA
[6] Medtron Sofamor Danek, Thoracolumbar Div, Memphis, TN USA
关键词
thoracic spine; biomechanics; pedicle screws; construct stiffness;
D O I
10.1097/01.brs.0000186590.45675.ce
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical study of different pedicle screw configuration usage on the thoracic spine using a cadaveric model. Objectives. To investigate the degree of motion afforded different pedicle screw configurations in the thoracic spine using a cadaveric model with 2 different degrees of intrinsic stability. Summary of Background Data. Recently, thoracic pedicle screws have become an alternative to hook and wire fixation, and have gained popularity. Clinically, pedicle screw use has ranged from application to every segment, to skipping every other level. There exists no clear consensus as to which strategy is most appropriate. Methods. The load-displacement behavior of 6 different constructs was determined on 8 fresh frozen cadaver spine specimens (T4-T12). Each construct was evaluated on 2 destabilization models, including minimum destabilization (bilateral facetectomy) and maximum destabilization (facetectomy and annulotomy). Pure moments were applied, and the resultant range of motion for each scenario was determined. Results. Facetectomy did not significantly destabilize the thoracic spine. Annulotomy and facetectomy created gross instability that rendered testing of this destabilization model impossible. All constructs significantly reduced the range of motion compared to intact or facetectomized specimens (P <= 0.001). When different constructs were compared to each other, a pattern of continuously increasing stability emerged, with the "maximum" construct being the most stable and "minimum" configuration being the least, with varying degrees of statistical significance. Conclusions. Our results suggest that the most important factor for the acute postoperative stability of spinal fixation is the degree of preoperative or iatrogenic destabilization. The minimum amount of pedicle screws provides adequate stability when there is minimal destabilization of the spine. On the other hand, when anterior column release has been performed or instability exists before surgery, segmental pedicle screw fixation may be necessary to achieve adequate stability.
引用
收藏
页码:2530 / 2537
页数:8
相关论文
共 39 条
[1]
The effect of transpedicular screw misplacement on late spinal stability [J].
Açikbas, SC ;
Arslan, FY ;
Tuncer, MR .
ACTA NEUROCHIRURGICA, 2003, 145 (11) :949-955
[2]
Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[3]
Adolescent idiopathic thoracic scoliosis: apical correction with specialized pedicle hooks [J].
Arlet, V ;
Papin, P ;
Marchesi, D ;
Aebi, M .
EUROPEAN SPINE JOURNAL, 1999, 8 (04) :266-271
[4]
Lumbar pedicle screws versus hooks - Results in double major curves in adolescent idiopathic scoliosis [J].
Barr, SJ ;
Schuette, AM ;
Emans, JB .
SPINE, 1997, 22 (12) :1369-1379
[5]
Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities [J].
Belmont, PJ ;
Klemme, WR ;
Robinson, M ;
Polly, DW .
SPINE, 2002, 27 (14) :1558-1566
[6]
In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[7]
Scoliosis correction maintenance in skeletally immature patients with idiopathic scoliosis - Is anterior fusion really necessary? [J].
Burton, DC ;
Asher, MA ;
Lai, SM .
SPINE, 2000, 25 (01) :61-68
[8]
THE STRENGTH AND STIFFNESS OF THORACIC IMPLANT ANCHORS IN OSTEOPOROTIC SPINES [J].
BUTLER, TE ;
ASHER, MA ;
JAYARAMAN, G ;
NUNLEY, PD ;
ROBINSON, RG .
SPINE, 1994, 19 (17) :1956-1962
[9]
Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries - Technique and short-term complications [J].
Carbone, JJ ;
Tortolani, J ;
Quartararo, LG .
SPINE, 2003, 28 (01) :91-97
[10]
Factor analysis of the effectiveness of transfixation and rod characteristics on the TSRH screw-rod instrumentation [J].
Deligianni, D ;
Korovessis, P ;
Baikousis, A ;
Misirlis, Y .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (01) :50-57