New coupling of planar chromatography with direct analysis in real time mass spectrometry

被引:146
作者
Morlock, Gertrud [1 ]
Ueda, Yoshihisa [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
关键词
planar chromatography; HPTLC/DART-TOF-MS; HPTLC/ESI-MS; DART;
D O I
10.1016/j.chroma.2006.12.056
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The coupling of planar chromatography with direct analysis in real time time-of-flight mass spectrometry (DART-TOF-MS) was shown for the first time. Cutting the plate within a track led to substance zones positioned on the plate edge which were directly introduced into the DART gas stream. Mass signals were obtained instantaneously within seconds. Detectability was shown in the very low ng-range per zone on the example of isopropylthioxanthone. The coupling was perfectly suited for identification and qualitative purposes, but it was initially critical for quantification of results. Analytical response (R(2) 0.8202) and repeatability were strongly dependent from proper manual positioning of the HPTLC plate into the electronic or vibronic excited-state gas stream of the ion source. This drawback was overcome by using stable isotope-labeled standards shown on the example of caffeine. This way, analytical response (R(2) 0.9892) and repeatability (RSD <+/- 5.4%, n = 6) were improved to a high extent. Spatial resolution by an in-house-built plate holder system was shown to be better than 3 turn. The decay of the signal was observed. The efficacy of this new coupling was compared to a plunger-based extraction device for HPTLC/electrospray ionisation-MS. The latter device showed delectability down to the pg-range, e.g. the limit of quantification for isopropylthioxanthone was found to be 100 pg. Repeatability was comparable (RSD +/- 6.7%), however, without the need of internal standard correction. Analytical response was slightly better and showed a determination coefficient R 2 of 0.9983. Similar data were obtained for caffeine as well. Spatial resolution was 2 nun or 4 mm depending on the plunger head used. The comparison showed that HPTLC/DART-TOF-MS is a useful coupling method regarding qualitative aspects and it has the potential to cope also with the difficulties of quantification if isotope-labeled standards were used or if a plate holder system is employed as initially shown. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 21 条
[1]   Improved online coupling of planar chromatography with electrospray mass spectrometry: extraction of zones from glass plates [J].
Alpmann, Alexander ;
Morlock, Gertrud .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) :1543-1551
[2]  
ARANDA M, 2006, J CHROMATOGR SCI
[3]  
ARANDA MA, UNPUB
[4]   Simultaneous determination of riboflavin, pyridoxine, nicotinamide, caffeine and taurine in energy drinks by planar chromatography-multiple detection with confirmation by electrospray ionization mass spectrometry [J].
Aranda, Mario ;
Morlock, Gertrud .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) :253-260
[5]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[6]   Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system [J].
Ford, MJ ;
Deibel, MA ;
Tomkins, BA ;
Van Berkel, GJ .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4385-4389
[7]  
JAUTZ U, 2005, P EUR FOOD CHEM 13, V2, P406
[8]   Validation of a new planar chromatographic method for quantification of the heterocyclic aromatic amines most frequently found in meat [J].
Jautz, Ute ;
Morlock, Gertrud .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (03) :1083-1093
[9]   Efficacy of planar chromatography coupled to (tandem) mass spectrometry for employment in trace analysis [J].
Jautz, Ute ;
Morlock, Gertrud .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) :244-250
[10]   Automation of a surface sampling probe/electrospray mass spectrometry system [J].
Kertesz, V ;
Ford, MJ ;
Van Berkel, GJ .
ANALYTICAL CHEMISTRY, 2005, 77 (22) :7183-7189