Simultaneous determination of riboflavin, pyridoxine, nicotinamide, caffeine and taurine in energy drinks by planar chromatography-multiple detection with confirmation by electrospray ionization mass spectrometry

被引:121
作者
Aranda, Mario [1 ]
Morlock, Gertrud [1 ]
机构
[1] Univ Hohenheim, Inst Food Chem, D-70599 Stuttgart, Germany
关键词
pyridoxine; riboflavin; nicotinamide; caffeine; taurine; HPTLC; HPTLC/MS; energy drinks; fluorescence;
D O I
10.1016/j.chroma.2006.07.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new high-throughput method was developed to detect simultaneously riboflavin (Vitamin B-2), pyridoxine (Vitamin B-6), nicotinamide (Vitamin B-3), caffeine and taurine in energy drinks by multiple detection. Ten samples of energy drinks and six samples of beverages containing caffeine were prepared by degassing in an ultrasonic bath for 20 min. After chromatography, multi-wavelength scanning was performed by: (1) UV-absorbance measurement at 261 nm for nicotinamide and 275 nm for caffeine, (2) fluorescence measurement at 366/> 400 and 313/> 340 nm for riboflavin and pyridoxine, respectively, and (3) Vis-absorbance measurement at 525 nm for taurine, after post-chromatographic derivatization with ninhydrin reagent. Calibrations were linear or polynomial with determination coefficients r(2) > 0.999. Overall recoveries of the five compounds were between 81 and 106% at three different concentration levels. Repeatabilities (RSD, %) of all substances in matrix were determined to be between 0.8 and 1.5%. Intermediate precisions (RSD, %) ranged between 3.6 and 7.4% for riboflavin, 2.8 and 6.3% for nicotinamide, 2.5 and 4.4% for caffeine, 2.1 and 2.9% for taurine and 0.5 and 4.0% for pyridoxine at different concentration levels. Mass confirmation was performed by a single quadrupole MS in positive electrospray ionisation (ESI) scan mode for all substances except taurine (negative mode). This method offers a good alternative for routine analysis due to its simplicity and at the same time reliability. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 57 条
[1]   HPTLC determination of caffeine in stimulant herbal products and power drinks [J].
Abourashed, EA ;
Mossa, JS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) :617-620
[2]   The effects of Red Bull Energy Drink on human performance and mood [J].
Alford, C ;
Cox, H ;
Wescott, R .
AMINO ACIDS, 2001, 21 (02) :139-150
[3]  
ALPMANN A, 2006, IN PRESS ANAL BIOANA
[4]   RP-HPLC Determination of vitamins B1, B3, B6, folic acid and B12 in multivitamin tablets [J].
Amidzic, R ;
Brboric, J ;
Cudina, O ;
Vladimirov, S .
JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2005, 70 (10) :1229-1235
[5]  
[Anonymous], 2005, INT C HARM ICH ICH H, P1
[6]   Simultaneous determination of caffeine, theobromine, theophylline, paraxanthine and nicotine in human milk by liquid chromatography with diode array UV detection [J].
Aresta, A ;
Palmisano, F ;
Zambonin, CG .
FOOD CHEMISTRY, 2005, 93 (01) :177-181
[7]   SEPARATION OF VITAMIN-B COMPLEX AND FOLIC-ACID USING TLC PLATES IMPREGNATED WITH SOME TRANSITION-METAL IONS [J].
BHUSHAN, R ;
PARSHAD, V .
BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (04) :196-198
[8]   Improved separation of vitamin B complex and folic acid using some new solvent systems and impregnated TLC [J].
Bhushan, R ;
Parshad, V .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (10) :1607-1623
[9]   Simultaneous determination of caffeine, theobromine, and theophylline by high-performance liquid chromatography [J].
Bispo, MS ;
Veloso, MCC ;
Pinheiro, HLC ;
De Oliveira, RFS ;
Reis, JON ;
De Andrade, JB .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (01) :45-48
[10]   Development of an LC-MS-MS method for the quantification of taurine derivatives in marine invertebrates [J].
Chaimbault, P ;
Alberic, P ;
Elfakir, C ;
Lafosse, M .
ANALYTICAL BIOCHEMISTRY, 2004, 332 (02) :215-225