Matrix-comprehensive in-house validation and robustness check of a confirmatory method for the determination of four nitrofuran metabolites in poultry muscle and shrimp by LC-MS/MS

被引:43
作者
Bock, Claudia [1 ]
Gowik, Petra [1 ]
Stachel, Carolin [1 ]
机构
[1] Fed Off Consumer Protect & Food Safety BVL, EU & Natl Reference Lab, D-10117 Berlin, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 856卷 / 1-2期
关键词
Nitrofurans; metabolite; validation; matrix-comprehensive in-house validation; muscle; shrimps; poultry; LC-MS/MS; residues; measurement uncertainty; robustness;
D O I
10.1016/j.jchromb.2007.05.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An already well-described method for the determination of nitrofuran metabolites 3-amino-5-methyl-morpholino-2-oxazolidinone (AMOZ), 3-amino-2-oxazolidinone (AOZ), semicarbazide (SEM) and 1-aminohydantoin (AHD) was adapted to the needs of our laboratory and checked for its robustness regarding sample conditions and the processing step. Using the same data, the method was validated and the measurement uncertainty was estimated. All criteria and requirements of Commission Decision 2002/657/EC were fulfilled. The CC, determined lies between 0.1 and 0.7 mu g/kg, the CC beta lies between 0.1 and 0.9 mu g/kg, the measurement uncertainty was estimated as being between 7 and 17% taking into account matrix, time and sample preparation influences. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 189
页数:12
相关论文
共 22 条
[11]   A top-down in-house validation based approach for the investigation of the measurement uncertainty using fractional factorial experiments [J].
Jülicher, B ;
Gowik, P ;
Uhlig, S .
ANALYST, 1999, 124 (04) :537-545
[12]   Assessment of detection methods in trace analysis by means of a statistically based in-house validation concept [J].
Jülicher, B ;
Gowik, P ;
Uhlig, S .
ANALYST, 1998, 123 (02) :173-179
[13]   Determination of the metabolites of nitrofuran antibiotics in animal tissue by high-performance liquid chromatography-tandem mass spectrometry [J].
Leitner, A ;
Zöllner, P ;
Lindner, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 939 (1-2) :49-58
[14]   Determination of the furazolidone metabolite, 3-amino-2-oxazolidinone, in porcine tissues using liquid chromatography-thermospray mass spectrometry and the occurrence of residues in pigs produced in Northern Ireland [J].
McCracken, RJ ;
Kennedy, DG .
JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01) :87-94
[15]   DETERMINATION OF FURAZOLIDONE IN PORCINE TISSUE USING THERMOSPRAY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AND A STUDY OF THE PHARMACOKINETICS AND STABILITY OF ITS RESIDUES [J].
MCCRACKEN, RJ ;
BLANCHFLOWER, WJ ;
ROWAN, C ;
MCCOY, MA ;
KENNEDY, DG .
ANALYST, 1995, 120 (09) :2347-2351
[16]  
McCracken RJ, 1997, FOOD ADDIT CONTAM, V14, P507, DOI 10.1080/02652039709374558
[17]   Quantitative determination of four nitrofuran metabolites in meat by isotope dilution liquid chromatography-electrospray ionisation-tandem mass spectrometry [J].
Mottier, P ;
Khong, SP ;
Gremaud, E ;
Richoz, J ;
Delatour, T ;
Goldmann, T ;
Guy, PA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1067 (1-2) :85-91
[18]   POSTMORTAL DEGRADATION OF FURAZOLIDONE AND FURALTADONE IN EDIBLE TISSUES OF CALVES [J].
NOUWS, JFM ;
LAURENSEN, J .
VETERINARY QUARTERLY, 1990, 12 (01) :56-59
[19]  
UHLIG, 2006, COMMUNICATION
[20]   Performance of a matrix-comprehensive in-house validation study by means of an especially designed software [J].
Uhlig, S ;
Gowik, P ;
Radeck, W .
ANALYTICA CHIMICA ACTA, 2003, 483 (1-2) :351-362