Effects of posture on FDTD calculations of specific absorption rate in a voxel model of the human body

被引:57
作者
Findlay, RP [1 ]
Dimbylow, PJ [1 ]
机构
[1] Natl Radiol Protect Board, Didcot OX11 0RQ, Oxon, England
关键词
D O I
10.1088/0031-9155/50/16/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A change in the posture of the human body can significantly affect the way in which it absorbs radiofrequency electromagnetic radiation. To study this, an anatomically realistic model of the body has been modified to develop new voxel models in postures other than the standard standing position with arms to the side. These postures were sitting, arms stretched out horizontally to the side and vertically above the head. Finite-difference time-domain (FDTD) calculations of the whole-body averaged specific energy absorption rate (SAR) have been performed from 10 MHz to 300 MHz at a resolution of 4 mm. Calculations show that the effect of a raised arm above the head posture was to increase the value of the whole-body averaged SAR at resonance by up to 35% when compared to the standard, arms by the side position. SAR values, both whole-body averaged and localized in the ankle, were used to derive the external electric field values required to produce the SAR basic restrictions of the ICNIRP guidelines. It was found that, in certain postures, external electric field reference levels alone would not provide a conservative estimate of localized SAR exposure and it would be necessary to invoke secondary reference levels on limb currents to provide compliance with restrictions.
引用
收藏
页码:3825 / 3835
页数:11
相关论文
共 17 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]   Empirical and theoretical dosimetry in support of whole body resonant RF exposure (100 MHz) in human volunteers [J].
Allen, SJ ;
Adair, ER ;
Mylacralne, KS ;
Hurt, W ;
Ziriax, J .
BIOELECTROMAGNETICS, 2003, 24 (07) :502-509
[3]  
[Anonymous], 2003, Ann ICRP, V32, P3
[4]   Magnetic field exposures for UK live-line workers [J].
Dawson, TW ;
Caputa, K ;
Stuchly, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07) :995-1012
[5]   Numerical evaluation of 60 Hz magnetic induction in the human body in complex occupational environments [J].
Dawson, TW ;
Caputa, K ;
Stuchly, MA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) :1025-1040
[6]   FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :479-490
[7]   Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz [J].
Dimbylow, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2835-2846
[8]   The calculation of localised SAR in a 2 mm resolution anatomically realistic model of the lower leg [J].
Dimbylow, PJ .
RADIATION PROTECTION DOSIMETRY, 1997, 72 (3-4) :321-326
[9]  
DIMBYLOW PJ, 1996, P INT WORKSH VOX PHA, P1
[10]   The dielectric properties of biological tissues .1. Literature survey [J].
Gabriel, C ;
Gabriel, S ;
Corthout, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2231-2249