Combined use of supported liquid membrane and solid-phase extraction to enhance selectivity and sensitivity in capillary electrophoresis for the determination of ochratoxin A in wine

被引:33
作者
Almeda, Sara [1 ]
Arce, Lourdes [1 ]
Valcarcel, Miguel [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
capillary electrophoresis; ochratoxin A; solid-phase extraction; supported liquid membrane; wine;
D O I
10.1002/elps.200700372
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper proposes a novel strategy to enhance selectivity and sensitivity in CE, using supported liquid membrane (SLM) and off-line SPE simultaneously. The determination of ochratoxin A (OA) in wine has been used to demonstrate the potential of this methodology. In the S LM step, the donor phase (either a 20 ml, volume of a standard solution at pH 1 or a wine sample at pH 8) was placed in a vial, where a micromembrane extraction unit accommodating the acceptor phase (1 mL water, pH 11) in its lumen was immersed. The SLM was constructed by impregnating a porous Fluoropore Teflon (PTFE) membrane with a water-immiscible organic solvent (octanol). In the off-line SPE step, the nonpolar sorbent (C-18, 4 mg) selectively retained the target ochratoxin, enabling small volumes of acceptor phase (1 mL) to be introduced. The captured analytes were eluted in a small volume of methanol (0.1 mL). This procedure resulted in sample cleanup and concentration enhancement. The method was evaluated for accuracy and precision, and its RSD found to be 5%. The LODs for OA in the standard solutions and wine samples were 0.5 and 30 mu g/L, respectively. The results obtained demonstrate that SLM combined with off-line is a good alternative to the use of immunoaffinity columns prior to CE analysis.
引用
收藏
页码:1573 / 1581
页数:9
相关论文
共 44 条
[1]   A convenient method for assessing mycotoxin production in cultures of aspergilli and penicillia [J].
Abramson, D ;
Clear, RM .
JOURNAL OF FOOD PROTECTION, 1996, 59 (06) :642-644
[2]  
Akiyama H, 1997, J FOOD HYG SOC JPN, V38, P406, DOI 10.3358/shokueishi.38.6_406
[3]   Direct determination of chlorophenols present in liquid samples by using a supported liquid membrane coupled in-line with capillary electrophoresis equipment [J].
Almeda, S. ;
Nozal, L. ;
Arce, L. ;
Valcarcel, M. .
ANALYTICA CHIMICA ACTA, 2007, 587 (01) :97-103
[4]  
*ASS OFF AN CHEM, 1990, OFF METH AN AOAC NAT, P1184
[5]   Determination of ochratoxin a in cereals and feed by SAX-SPE clean up and LC fluorimetric detection [J].
Biancardi, A ;
Riberzani, A .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (15) :2395-2407
[6]  
Bohs B, 1995, CHROMATOGRAPHIA, V41, P631, DOI 10.1007/BF02267796
[7]   Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips [J].
Breadmore, Michael C. .
ELECTROPHORESIS, 2007, 28 (1-2) :254-281
[8]  
Breitholtz-Emanuelsson Anna, 1993, Natural Toxins, V1, P347, DOI 10.1002/nt.2620010605
[9]  
BREITHOLTZEMANUELSSON A, 1993, J AOAC INT, V76, P842
[10]   QUANTIFICATION OF OCHRATOXIN-A IN SWINE KIDNEYS BY ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING A SIMPLIFIED SAMPLE PREPARATION PROCEDURE [J].
CLARKE, JR ;
MARQUARDT, RR ;
FROHLICH, AA ;
PITURA, RJ .
JOURNAL OF FOOD PROTECTION, 1994, 57 (11) :991-995