High-resolution 3D proton spectroscopic imaging of the human brain at 3 T:: SNR issues and application for anatomy-matched voxel sizes

被引:53
作者
Gruber, S
Mlynárik, V
Moser, E
机构
[1] Univ Vienna, Inst Med Phys, NMR Grp, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Radiodiagnost, A-1090 Vienna, Austria
关键词
proton spectroscopic imaging; high field; brain; segmentation; brain tumor; Pelizaeus Merzbacher disease;
D O I
10.1002/mrm.10377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In a systematic study on the interdependence of linewidth, signal-to-noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging (H-1-SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High-precision quantitative data (0.75-0.094 cm(3)) were obtained for all resolutions, enabling the creation of metabolic maps that display details such as the ventricles, sulci, and gyri. High-resolution H-1-SI allows differences in metabolic ratios to be estimated for anatomically defined regions in gray (GM) and white matter (WM). Seven distinct regions in a healthy brain were anatomically segmented and their metabolic ratios were compared quantitatively. Data from a tumor patient are also presented to demonstrate potential clinical applications. Because of the high resolution, the metabolite ratios could be determined for distinct pathologic regions within the tumor and its surroundings. The method was additionally applied to a patient with patchy Pelizaeus Merzbacher disease (PMD), and compared to single-voxel spectroscopy performed in the same session. High-resolution Sl data were demonstrated in our study to allow the direct matching of anatomic and metabolic images. This may enhance the clinical value of H-1-SI. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 34 条
  • [1] Single-voxel proton MRS of the human brain at 1.5T and 3.0T
    Barker, PB
    Hearshen, DO
    Boska, MD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 765 - 769
  • [2] SELECTION OF OPTIMUM PARAMETERS FOR PULSE FOURIER-TRANSFORM NUCLEAR MAGNETIC-RESONANCE
    BECKER, ED
    FERRETTI, JA
    GAMBHIR, PN
    [J]. ANALYTICAL CHEMISTRY, 1979, 51 (09) : 1413 - 1420
  • [3] 3D PHASE ENCODING H-1 SPECTROSCOPIC IMAGING OF HUMAN BRAIN
    DUIJN, JH
    MATSON, GB
    MAUDSLEY, AA
    WEINER, MW
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (02) : 315 - 319
  • [4] LOCALIZED HIGH-RESOLUTION PROTON NMR-SPECTROSCOPY USING STIMULATED ECHOES - INITIAL APPLICATIONS TO HUMAN-BRAIN INVIVO
    FRAHM, J
    BRUHN, H
    GYNGELL, ML
    MERBOLDT, KD
    HANICKE, W
    SAUTER, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) : 79 - 93
  • [5] 3D localized in vivo H-1 spectroscopy of human brain by using a hybrid of 1D-Hadamard with 2D chemical shift imaging
    Gonen, O
    AriasMendoza, F
    Goelman, G
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) : 644 - 650
  • [6] Gonen O, 2001, AM J NEURORADIOL, V22, P1727
  • [7] GRUBER S, 2000, MAGN RESON MATER PHY, V11, P186
  • [8] GRUBER S, 2000, MAGN RESON MATER PHY, V11, P82
  • [9] AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS
    GRUETTER, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 804 - 811
  • [10] Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength
    Gruetter, R
    Weisdorf, SA
    Rajanayagan, V
    Terpstra, M
    Merkle, H
    Truwit, CL
    Garwood, M
    Nyberg, SL
    Ugurbil, K
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1998, 135 (01) : 260 - 264