Correction of the interference by mixing the reagents in the bioluminescent determination of ATP in environmental samples by an interfaced PC photometer and a robust regression procedure

被引:9
作者
Mecozzi, M [1 ]
Amici, M [1 ]
Visco, G [1 ]
机构
[1] UNIV ROMA LA SAPIENZA, ROME, ITALY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 06期
关键词
D O I
10.1007/s002160050242
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated procedure for correcting the interference due to mixing the reagents in the determination of ATP by a bioluminescent technique is described. The measurements were performed by an in-house interfaced PC photometer. An automated procedure based on a robust regression method and outliers detection was applied to exclude the time of the mixing of the reagents from the global time of reaction. In fact the mixing of the reagents is responsible of the poor analytical precision (RSD% > 25) and low sensitivity (limit of detection approximate to 2 x 10(-8) mol/l). By this procedure, the precision (RSD% < 7) and sensitivity (limit of detection approximate to 8 x 10(-10) mol/l) were improved. The method was applied to the determination of ATP in marine sediments and good recovery within 90-108% was obtained. For non-polluted samples the measurement can be carried out by direct comparison with standard solutions. The standard addition procedure is recommended for polluted samples.
引用
收藏
页码:747 / 751
页数:5
相关论文
共 34 条
[1]  
[Anonymous], 1988, ANALYST, V113, P1469
[2]   FIREFLY LUCIFERASE ASSAY OF ADENOSINE-TRIPHOSPHATE AS A TOOL OF QUANTITATION OF THE VIABILITY OF BCG VACCINES [J].
ASKGAARD, DS ;
GOTTSCHAU, A ;
KNUDSEN, K ;
BENNEDSEN, J .
BIOLOGICALS, 1995, 23 (01) :55-60
[3]   EXTRACTION AND MEASUREMENT OF ADENOSINE-TRIPHOSPHATE FROM MARINE-SEDIMENTS [J].
BANCROFT, K ;
PAUL, EA ;
WIEBE, WJ .
LIMNOLOGY AND OCEANOGRAPHY, 1976, 21 (03) :473-479
[4]   ATP-Bioluminescence Techniques for Assessing the Hygienic Condition of Milk Transport Tankers [J].
Bell, C. ;
Stallard, P. A. ;
Brown, S. E. ;
Standley, J. T. E. .
INTERNATIONAL DAIRY JOURNAL, 1994, 4 (07) :629-640
[6]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[7]   INTERACTION OF LONG-CHAIN CHOLINE DERIVATIVES WITH FIREFLY LUCIFERASE AND THEIR USE AS REAGENTS FOR THE EXTRACTION OF INTRACELLULAR ATP FROM MICROORGANISMS [J].
DUKHOVICH, A ;
RODRIGUEZ, MJ ;
GAONA, LG ;
LEVASHOV, A ;
UGAROVA, N .
ANALYTICA CHIMICA ACTA, 1995, 303 (01) :85-90
[8]   OBTAINING AND PROCESSING DATA FROM LABORATORY INSTRUMENTS .1. GETTING THE DATA INTO THE WINDOWS ENVIRONMENT [J].
FENNEMA, BDJR ;
FORSTER, RJ ;
VOS, JG ;
HUGHES, G ;
DIAMOND, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (01) :1-3
[9]   OBTAINING AND PROCESSING DATA FROM LABORATORY INSTRUMENTS .2. PROCESSING THE DATA USING EXCEL [J].
FENNEMA, BDJR ;
FORSTER, RJ ;
VOS, JG ;
HUGHES, G ;
DIAMOND, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (02) :37-40
[10]   Determination of ATP using chelation-enhanced fluorescence [J].
Foy, GP ;
Pacey, GE .
TALANTA, 1996, 43 (02) :225-232