Molecularly imprinted polymer solid-phase extraction coupled to square wave voltammetry at carbon fibre microelectrodes for the determination of fenbendazole in beef liver

被引:32
作者
de Prada, A. Guzman-Vazquez
Loaiza, Oscar A.
Serra, B.
Morales, D.
Martinez-Ruiz, P.
Reviejo, A. J.
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
[2] Univ Complutense Madrid, Fac Chem, Dept Organ Chem, E-28040 Madrid, Spain
关键词
benzimidazoles; fenbendazole; molecularly imprinted polymer; square wave voltammetry; beef liver;
D O I
10.1007/s00216-007-1233-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A molecularly imprinted polymer was developed and used for solid-phase extraction (MISPE) of the antihelmintic fenbendazole in beef liver samples. Detection of the analyte was accomplished using square wave voltammetry (SWV) at a cylindrical carbon fibre microelectrode (CFME). A mixture of MeOH/HAc (9:1) was employed both as eluent in the MISPE system and as working medium for electrochemical detection of fenbendazole. The limit of detection was 1.9x10(-7) mol L-1 (57 mu g L-1), which was appropriate for the determination of fenbendazole at the maximum residue level permitted by the European Commission (500 mu g kg(-1) in liver). Given that the SW voltammetric analysis could not be directly performed in the sample extract as a consequence of interference from some sample components, a sample clean-up with a MIP for selectively retaining fenbendazole was performed. The MIP was synthesized using a 1:8:22 template/methacrylic acid/ethylene glycol dimethacrylate ratio. A Britton-Robinson Buffer of pH 9.0 was selected for retaining fenbendazole in the MIP cartridges, and an eluent volume of 5.0 mL at a flow rate of 2.0 mL min(-1) was chosen in the elution step. Cross-reactivity with the MIP was observed for other benzimidazoles. The synthesized MIP exhibited a good selectivity for benzimidazoles with respect to other veterinary drugs. The applicability of the MISPE-SWV method was tested with beef liver samples, spiked with fenbendazole at 5,000 and 500 mu g kg(-1). Results obtained for ten different liver samples yielded mean recoveries of (95 +/- 12)% and (96 +/- 11)% for the upper and lower concentration level, respectively.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 32 条
[1]   ANALYTICAL APPLICATIONS OF CYLINDRICAL CARBON-FIBER MICROELECTRODES - SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANTS IN FOOD [J].
AGUI, ML ;
REVIEJO, AJ ;
YANEZSEDENO, P ;
PINGARRON, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2195-2200
[2]   Towards molecular-imprint based SPE of local anaesthetics [J].
Andersson, LI ;
Abdel-Rehim, M ;
Nicklasson, L ;
Schweitz, L ;
Nilsson, S .
CHROMATOGRAPHIA, 2002, 55 (Suppl 1) :S65-S69
[3]   Efficient sample pre-concentration of bupivacaine from human plasma by solid-phase extraction on molecularly imprinted polymers [J].
Andersson, LI .
ANALYST, 2000, 125 (09) :1515-1517
[4]   THEORY OF ULTRAMICROELECTRODES [J].
AOKI, K .
ELECTROANALYSIS, 1993, 5 (08) :627-639
[5]   Determination of benzimidazole residues using liquid chromatography and tandem mass spectrometry [J].
Balizs, G .
JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2) :167-177
[6]  
BALIZS G, 1998, INT S HORM VET DRUG
[7]   On-line solid-phase extraction of triazine herbicides using a molecularly imprinted polymer for selective sample enrichment [J].
Bjarnason, B ;
Chimuka, L ;
Ramström, O .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2152-2156
[8]   Use of molecularly imprinted polymers in the solid-phase extraction of clenbuterol from animal feeds and biological matrices [J].
Brambilla, G ;
Fiori, M ;
Rizzo, B ;
Crescenzi, V ;
Masci, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 759 (01) :27-32
[9]   Clean-up of triazines in vegetable extracts by molecularly-imprinted solid-phase extraction using a propazine-imprinted polymer [J].
Cacho, C ;
Turiel, E ;
Martín-Esteban, A ;
Pérez-Conde, C ;
Cámara, C .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) :491-496
[10]   Retention mechanism of analytes in the solid-phase extraction process using molecularly imprinted polymers - Application to the extraction of triazines from complex matrices [J].
Chapuis, F ;
Pichon, V ;
Lanza, F ;
Sellergren, B ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01) :93-101