Molecularly imprinted polymer solid-phase extraction coupled to square wave voltammetry at carbon fibre microelectrodes for the determination of fenbendazole in beef liver

被引:32
作者
de Prada, A. Guzman-Vazquez
Loaiza, Oscar A.
Serra, B.
Morales, D.
Martinez-Ruiz, P.
Reviejo, A. J.
Pingarron, J. M. [1 ]
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
[2] Univ Complutense Madrid, Fac Chem, Dept Organ Chem, E-28040 Madrid, Spain
关键词
benzimidazoles; fenbendazole; molecularly imprinted polymer; square wave voltammetry; beef liver;
D O I
10.1007/s00216-007-1233-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A molecularly imprinted polymer was developed and used for solid-phase extraction (MISPE) of the antihelmintic fenbendazole in beef liver samples. Detection of the analyte was accomplished using square wave voltammetry (SWV) at a cylindrical carbon fibre microelectrode (CFME). A mixture of MeOH/HAc (9:1) was employed both as eluent in the MISPE system and as working medium for electrochemical detection of fenbendazole. The limit of detection was 1.9x10(-7) mol L-1 (57 mu g L-1), which was appropriate for the determination of fenbendazole at the maximum residue level permitted by the European Commission (500 mu g kg(-1) in liver). Given that the SW voltammetric analysis could not be directly performed in the sample extract as a consequence of interference from some sample components, a sample clean-up with a MIP for selectively retaining fenbendazole was performed. The MIP was synthesized using a 1:8:22 template/methacrylic acid/ethylene glycol dimethacrylate ratio. A Britton-Robinson Buffer of pH 9.0 was selected for retaining fenbendazole in the MIP cartridges, and an eluent volume of 5.0 mL at a flow rate of 2.0 mL min(-1) was chosen in the elution step. Cross-reactivity with the MIP was observed for other benzimidazoles. The synthesized MIP exhibited a good selectivity for benzimidazoles with respect to other veterinary drugs. The applicability of the MISPE-SWV method was tested with beef liver samples, spiked with fenbendazole at 5,000 and 500 mu g kg(-1). Results obtained for ten different liver samples yielded mean recoveries of (95 +/- 12)% and (96 +/- 11)% for the upper and lower concentration level, respectively.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 32 条
[21]   Comparison of milk residue profiles after oral and subcutaneous administration of benzimidazole anthelmintics to dairy cows [J].
Moreno, L ;
Imperiale, F ;
Mottier, L ;
Alvarez, L ;
Lanusse, C .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :91-99
[22]   Quantitative chromatographic determination of several benzimidazole anthelmintic molecules in parasite material [J].
Mottier, L ;
Alvarez, L ;
Lanusse, C .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 798 (01) :117-125
[23]   DETERMINATION OF CLENBUTEROL IN BOVINE URINE BY ENZYME-IMMUNOASSAY FOLLOWING CONCENTRATION AND CLEANUP BY IMMUNOAFFINITY CHROMATOGRAPHY [J].
PICKETT, RJH ;
SAUER, MJ .
ANALYTICA CHIMICA ACTA, 1993, 275 (1-2) :269-273
[24]   DIRECT DRUG DETERMINATION BY SELECTIVE SAMPLE ENRICHMENT ON AN IMPRINTED POLYMER [J].
SELLERGREN, B .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1578-1582
[25]  
SELLERGREN B, 2001, TECH INSTRUM ANAL CH, V15, P355
[26]   Molecularly imprinted polyacrylic acid containing multiple recognition sites for steroids [J].
Sreenivasan, K .
JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 82 (04) :889-893
[27]   Preparation of a molecularly imprinted polymer for the solid-phase extraction of scopolamine with hyoscyamine as a dummy template molecule [J].
Theodoridis, G ;
Kantifes, A ;
Manesiotis, P ;
Raikos, N ;
Tsoukali-Papadopoulou, H .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :103-109
[28]   Selective solid-phase extraction sorbent for caffeine made by molecular imprinting [J].
Theodoridis, G ;
Manesiotis, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :163-169
[29]   Capillary electrophoresis with (R)-(-)-N-(3,5-dinitrobenzoyl)-α-phenylglycine as chiral selector for separation of albendazole sulfoxide enantiomers and their analysis in human plasma [J].
Thormann, W ;
Prost, F ;
Procházková, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (3-4) :555-567
[30]   Flow chemiluminescence sensor for determination of clenbuterol based on molecularly imprinted polymer [J].
Zhou, HJ ;
Zhang, ZJ ;
He, DY ;
Hu, YF ;
Huang, Y ;
Chen, DL .
ANALYTICA CHIMICA ACTA, 2004, 523 (02) :237-242