Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
被引:6
作者:
Campbell, David
论文数: 0引用数: 0
h-index: 0
机构:
Repatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, AustraliaRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Campbell, David
[1
]
Mercer, Graham
论文数: 0引用数: 0
h-index: 0
机构:
Repatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, AustraliaRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Mercer, Graham
[1
]
Nilsson, Kjell-Gunnar
论文数: 0引用数: 0
h-index: 0
机构:
Umea Univ Hosp, Dept Orthopaed, S-90185 Umea, SwedenRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Nilsson, Kjell-Gunnar
[2
]
Wells, Vanessa
论文数: 0引用数: 0
h-index: 0
机构:
Repatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, AustraliaRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Wells, Vanessa
[1
]
Field, John R.
论文数: 0引用数: 0
h-index: 0
机构:
Flinders Univ S Australia, CORe Comparat Orthopaed Res Surg Facil, Adelaide, SA, AustraliaRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Field, John R.
[3
]
Callary, Stuart A.
论文数: 0引用数: 0
h-index: 0
机构:
Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA 5000, AustraliaRepatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
Callary, Stuart A.
[4
]
机构:
[1] Repatriat Gen Hosp, Orthopaed Unit, Adelaide, SA, Australia
[2] Umea Univ Hosp, Dept Orthopaed, S-90185 Umea, Sweden
[3] Flinders Univ S Australia, CORe Comparat Orthopaed Res Surg Facil, Adelaide, SA, Australia
[4] Royal Adelaide Hosp, Dept Orthopaed & Trauma, Adelaide, SA 5000, Australia
Wear induced peri-prosthetic osteolysis and aseptic loosening remain the major contributing factors to failure of total hip arthroplasty. To reduce wear particles from acetabular liners, the process of polyethylene cross-linking has been modified. In this study, we examine the wear of Marathon (TM) acetabular liners using Radiostereometric Analysis. Thirty patients were enrolled in a prospective cohort study. Femoral head penetration was calculated for 25 patients at 6 months, 1 and 2 years postoperatively. The mean proximal head penetration was 0.067 mm at 6 months, 0.113 mm at 1 year and 0.120 mm at 2 years. The mean three-dimensional femoral head penetration was 0.240 mm at 6 months, 0.230 mm at 1 year and 0.232 mm at 2 years. For both parameters, there was no measurable wear between 1 and 2 years, and the mean annual linear wear was less than 0.06 mm/year, which is less than the suggested osteolysis threshold for polyethylene. All patients demonstrated a dramatic improvement in clinical scores. These results were comparable with other studies that used alternative techniques with conventional radiography to evaluate wear for Marathon (TM). Long-term studies using the RSA method are recommended to further quantify the clinical performance of this polyethylene liner.
机构:
Washington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USAWashington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USA
Clohisy, JC
;
论文数: 引用数:
h-index:
机构:
Calvert, G
;
Tull, F
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USAWashington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USA
机构:
Washington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USAWashington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USA
Clohisy, JC
;
论文数: 引用数:
h-index:
机构:
Calvert, G
;
Tull, F
论文数: 0引用数: 0
h-index: 0
机构:
Washington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USAWashington Univ, Barnes Jewish Hosp, Dept Orthopaed Surg, St Louis, MO 63130 USA