Exchange-biased planar Hall effect sensor optimized for biosensor applications

被引:34
作者
Damsgaard, Christian D. [1 ]
Freitas, Susana C. [2 ,3 ]
Freitas, Paulo P. [2 ,3 ]
Hansen, Mikkel F. [1 ]
机构
[1] Tech Univ Denmark, MIC Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] INESC Microsyst & Nanotechnol, P-1000029 Lisbon, Portugal
[3] Inst Super Tecn, Dept Phys, P-1000 Lisbon, Portugal
关键词
D O I
10.1063/1.2830008
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article presents experimental investigations of exchange-biased Permalloy planar Hall effect sensor crosses with a fixed active area of w x w = 40 x 40 mu m(2) and Permalloy thicknesses of t = 20, 30, and 50 nm. It is shown that a single domain model describes the system well and that the thicker film will have a higher signal as well as a lower noise. It is estimated that the signal-to-noise ratio for bead detection increases by a factor 2.1 when t is increased from 20 to 50 nm and hence a higher t is beneficial for biosensor applications. This is exemplified with calculations on M-280 Dynabeads (R). (c) 2008 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 11 条
[1]  
DAMSGAARD CD, UNPUB
[2]   Magnetic microbead detection using the planar Hall effect [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :677-684
[3]   Planar Hall effect sensor for magnetic micro- and nanobead detection [J].
Ejsing, L ;
Hansen, MF ;
Menon, AK ;
Ferreira, HA ;
Graham, DL ;
Freitas, PP .
APPLIED PHYSICS LETTERS, 2004, 84 (23) :4729-4731
[4]   HALL EFFECT IN PERMALLOYS [J].
FONER, S .
PHYSICAL REVIEW, 1955, 99 (04) :1079-1081
[5]   Characterisation of Dynabeads® by magnetization measurements and Mossbauer spectroscopy [J].
Fonnum, G ;
Johansson, C ;
Molteberg, A ;
Morup, S ;
Aksnes, E .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :41-47
[6]  
FREITAS PP, 2004, MAGNETOELECTRONICS M, pD317
[7]   Ion beam deposition of Mn-Ir spin valves [J].
Gehanno, V ;
Freitas, PP ;
Veloso, A ;
Ferreira, J ;
Almeida, B ;
Sousa, JB ;
Kling, A ;
Soares, JC ;
da Silva, MF .
IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (05) :4361-4367
[8]   Magnetic biochips: a new option for sensitive diagnostics [J].
Megens, M ;
Prins, M .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) :702-708
[9]   LOW-FIELD MAGNETIC SENSORS BASED ON THE PLANAR HALL-EFFECT [J].
SCHUHL, A ;
VANDAU, FN ;
CHILDRESS, JR .
APPLIED PHYSICS LETTERS, 1995, 66 (20) :2751-2753
[10]   Thickness dependence of parallel and perpendicular anisotropic resistivity in Ta/NiFe/IrMn/Ta multilayer studied by anisotropic magnetoresistance and planar Hall effect [J].
Thanh, N. T. ;
Tu, L. T. ;
Ha, N. D. ;
Kim, C. O. ;
Kim, CheolGi ;
Shin, K. H. ;
Rao, B. Parvatheeswara .
JOURNAL OF APPLIED PHYSICS, 2007, 101 (05)