Tracking optical coherence tomography

被引:95
作者
Ferguson, RD
Hammer, DX
Paunescu, LA
Beaton, S
Schuman, JS
机构
[1] Phys Sci Inc, Andover, MA 01810 USA
[2] Tufts Univ New England Med Ctr, Ctr Eye, Boston, MA 02111 USA
关键词
D O I
10.1364/OL.29.002139
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An experimental tracking optical coherence tomography (OCT) system has been clinically tested. The prototype instrument uses a secondary sensing beam and steering mirrors to compensate for eye motion with a closed-loop bandwidth of 1 kHz and tracking accuracy, to within less than the OCT beam diameter. The retinal tracker improved image registration accuracy to <1 transverse pixel (<60 mum). Composite OCT images averaged over multiple scans and visits show a sharp fine structure limited only by transverse pixel size. As the resolution of clinical OCT systems improves, the capability to reproducibly map complex structures in the living eye at high resolution will lead to improved understanding of disease processes and improved sensitivity and specificity of diagnostic procedures. (C) 2004 Optical Society of America.
引用
收藏
页码:2139 / 2141
页数:3
相关论文
共 8 条
[1]   High-resolution optical coherence microscopy for high-speed, in vivo cellular imaging [J].
Aguirre, AD ;
Hsiung, P ;
Ko, TH ;
Hartl, I ;
Fujimoto, JG .
OPTICS LETTERS, 2003, 28 (21) :2064-2066
[2]   In vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer by polarization-sensitive optical coherence tomography [J].
Cense, B ;
Chen, TC ;
Park, BH ;
Pierce, MC ;
de Boer, JF .
OPTICS LETTERS, 2002, 27 (18) :1610-1612
[3]  
Ferguson R. D., 1998, U.S. patent, Patent No. [5(767), 941, 5767941]
[4]   Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes [J].
Guedes, V ;
Schuman, JS ;
Hertzmark, E ;
Wollstein, G ;
Correnti, A ;
Mancini, R ;
Lederer, D ;
Voskanian, S ;
Velazquez, L ;
Pakter, HM ;
Pedut-Kloizman, T ;
Fujimoto, JG ;
Mattox, C .
OPHTHALMOLOGY, 2003, 110 (01) :177-189
[5]   Compact scanning laser ophthalmoscope with high-speed retinal tracker [J].
Hammer, DX ;
Ferguson, RD ;
Magill, JC ;
White, MA ;
Elsner, AE ;
Webb, RH .
APPLIED OPTICS, 2003, 42 (22) :4621-4632
[6]   In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography [J].
Nassif, N ;
Cense, B ;
Park, BH ;
Yun, SH ;
Chen, TC ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS LETTERS, 2004, 29 (05) :480-482
[7]   Real-time, high velocity-resolution color Doppler optical coherence tomography [J].
Westphal, V ;
Yazdanfar, S ;
Rollins, AM ;
Izatt, JA .
OPTICS LETTERS, 2002, 27 (01) :34-36
[8]   Full range complex spectral optical coherence tomography technique in eye imaging [J].
Wojtkowski, M ;
Kowalczyk, A ;
Leitgeb, R ;
Fercher, AF .
OPTICS LETTERS, 2002, 27 (16) :1415-1417