Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes

被引:336
作者
Guedes, V
Schuman, JS
Hertzmark, E
Wollstein, G
Correnti, A
Mancini, R
Lederer, D
Voskanian, S
Velazquez, L
Pakter, HM
Pedut-Kloizman, T
Fujimoto, JG
Mattox, C
机构
[1] Tufts Univ, Sch Med, New England Eye Ctr, Boston, MA 02111 USA
[2] Univ Sao Paulo, Dept Oftalmol, Sao Paulo, Brazil
[3] Ist Benjamin Constant, Dept Glaucoma, Rio De Janeiro, Brazil
[4] Harvard Univ, Sch Publ Hlth, Dept Epidemiol, Boston, MA 02115 USA
[5] Univ Fed Rio Grande Sul, Dept Med Social, BR-90046900 Porto Alegre, RS, Brazil
[6] MIT, Cambridge, MA 02139 USA
关键词
D O I
10.1016/S0161-6420(02)01564-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the hypothesis that macular thickness correlates with the diagnosis of glaucoma. Design: Cross-sectional study. Participants: We studied 367 subjects (534 eyes), including 166 eyes of 109 normal subjects, 83 eyes of 58 glaucoma suspects, 196 eyes of 132 early glaucoma patients, and 89 eyes of 68 advanced glaucoma patients. Methods: We used optical coherence tomography (OCT) to measure macular and nerve fiber layer (NFL) thickness and to analyze their correlation with each other and with glaucoma status. We used both the commercial and prototype OCT units and evaluated correspondence between measurements performed on the same eyes on the same days. Main Outcome Measure: Macular and NFL thickness as measured by OCT. Results: All NFL parameters both in prototype and commercial OCT units were statistically significantly different comparing normal subjects and either early or advanced glaucoma (P < 0.001). Inner ring, outer ring, and mean macular thickness both in prototype and commercial OCT devices were found to be significantly different between normal subjects and advanced glaucomatous eyes (P < 0.001). The outer ring was the only macular parameter that could significantly differentiate between normal and early glaucoma with either the prototype or commercial OCT unit (P = 0.003, P = 0.008, respectively). The area under the receiver operator characteristic (AROC) curves comparing mean NFL thickness between normal and advanced glaucomatous eyes was 1.00 for both the prototype and commercial OCT devices for eyes scanned on both machines on the same day. The AROC comparing mean macular thickness in normal and advanced glaucomatous eyes scanned on both machines on the same day was 0.88 for the prototype OCT device and 0.80 for the commercial OCT. Conclusions: Both macular and NFL thickness as measured by OCT showed statistically significant correlations with glaucoma, although NFL thickness showed a stronger association than macular thickness. There was good correspondence between findings using both the prototype and commercial OCT units. Macular and NFL thickness measurements made with OCT may have usefulness in the clinical assessment of glaucoma. (C) 2003 by the American Academy of Ophthalmology.
引用
收藏
页码:177 / 189
页数:13
相关论文
共 29 条
[1]   Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography [J].
Blumenthal, EZ ;
Williams, JM ;
Weinreb, RN ;
Girkin, CA ;
Berry, CC ;
Zangwill, LM .
OPHTHALMOLOGY, 2000, 107 (12) :2278-2282
[2]  
Bowd C, 2000, ARCH OPHTHALMOL-CHIC, V118, P22
[3]  
Frishman LJ, 1996, INVEST OPHTH VIS SCI, V37, P125
[4]  
Garway-Heath DF, 2000, INVEST OPHTH VIS SCI, V41, P1774
[5]  
GLOVINSKY Y, 1993, INVEST OPHTH VIS SCI, V34, P395
[6]  
GUEDES V, 2001, REV BRAS OFTALMOL, V60, P152
[7]  
HART WM, 1982, OPHTHALMOLOGY, V89, P268
[8]  
Harwerth RS, 1999, INVEST OPHTH VIS SCI, V40, P2242
[9]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181