Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation

被引:139
作者
Beekman, FJ
de Jong, HWAM
van Geloven, S
机构
[1] Univ Utrecht, Med Ctr, Dept Nucl Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Ctr Med, Image Sci Inst, Dept Nucl Med, NL-3584 CX Utrecht, Netherlands
关键词
dual matrix reconstruction; image reconstruction; single photon emission computed tomography; monte carlo methods; scattering;
D O I
10.1109/TMI.2002.803130
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Quantitative accuracy of single photon emission computed tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general method for detailed modeling of scatter, but to date, fully three-dimensional (3-D) MCS-based statistical SPECT reconstruction approaches have not been realized, due to prohibitively long computation times and excessive computer memory requirements. MCS-based reconstruction has previously been restricted to two-dimensional approaches that are vastly inferior to fully 3-D reconstruction. Instead of MCS, scatter calculations based on simplified but less accurate models are sometimes incorporated in fully 3-D SPECT reconstruction algorithms. We developed a computationally efficient fully 3-D MCS-based reconstruction architecture by combining the following methods: 1) a dual matrix ordered subset (DM-OS) reconstruction algorithm to accelerate the reconstruction and avoid massive transition matrix precalculation and storage; 2) a stochastic photon transport calculation in MCS is combined with an analytic detector modeling step to reduce noise in the Monte Carlo (MC)-based reprojection after only a small number of photon histories have been tracked; and 3) the number of photon histories simulated is reduced by an order of magnitude in early iterations, or photon histories calculated in an early iteration are reused. For a 64 x 64 x 64 image array, the reconstruction time required for ten DM-OS iterations is approximately 30 min on a dual processor (AMD 1.4 GHz) PC, in which case the stochastic nature of MCS modeling is found to have a negligible effect on noise in reconstructions. Since MCS can calculate photon transport for any clinically used photon energy and patient attenuation distribution, the proposed methodology is expected to be useful for obtaining highly accurate quantitative SPECT images within clinically acceptable computation times.
引用
收藏
页码:867 / 877
页数:11
相关论文
共 52 条
[1]   A slice-by-slice blurring model and kernel evaluation using the Klein-Nishina formula for 3D scatter compensation in parallel and converging beam SPECT [J].
Bai, CY ;
Zeng, GSL ;
Gullberg, GT .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05) :1275-1307
[2]  
BECK JW, 1982, IEEE T NUCL SCI, V29, P506, DOI 10.1109/TNS.1982.4335896
[3]   Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study [J].
Beekman, FJ ;
Kamphuis, C ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1619-1632
[4]   SPECT scatter modelling in non-uniform attenuating objects [J].
Beekman, FJ ;
denHarder, JM ;
Viergever, MA ;
vanRijk, PP .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) :1133-1142
[5]   FAST SPECT SIMULATION INCLUDING OBJECT SHAPE DEPENDENT SCATTER [J].
BEEKMAN, FJ ;
VIERGEVER, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) :271-282
[6]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[7]   Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation [J].
Beekman, FJ ;
de Jong, HWAM ;
Slijpen, ETP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) :N183-N192
[8]   Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation [J].
Beekman, FJ ;
Kamphuis, C ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) :491-499
[9]   Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography [J].
Beekman, FJ ;
Kamphuis, C ;
King, MA ;
van Rijk, PP ;
Viergever, MA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2001, 25 (02) :135-146
[10]  
BOWSHER JE, 1991, J NUCL MED, V32, P1285